3 | Components
Service manual
61
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
c Damper
11 Remove the 3 dampers from the compressor.
INFORMATION
The compressor dampers may look different.
12 Remove the bushings and keep them for re-use.
13 To install the compressor, see "Repair procedures"[455].
To install the compressor
1 Check the state of the dampers. Replace if worn.
2 Install the 3 dampers in the correct location on the unit.
A Class 20~35 unit
a Nut
b Compressor
c Damper
b
a
c
a
c
A
A Class 42~71 unit
a Nut
b Compressor
c Damper