3 | Components
Service manual
99
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
2 Cut the tie strap and unlock the ferrite core.
a
c
d
b
c
dd e f
a Ferrite core
b DC fan motor wiring harness
c Hook
d Screw (fan motor cover)
e Fan motor cover
f Wiring harness retainer
3 Route the DC fan motor wiring harness out of the hooks.
4 Remove the 3 screws and remove the fan motor cover.
5 Unfasten the hooks and remove the wiring harness retainer.
6 Route the DC fan motor wiring harness out of the hooks (behind the harness
retainer).
7 Remove the DC fan motor assembly from the indoor unit.
8 To install the DC fan motor assembly, see "Repair procedures"[496].
To install the DC fan motor assembly
1 Install the DC fan motor assembly on the fan motor cover.
2 Install the fan motor cover with DC fan motor assembly on the correct
location.
3 Install and tighten the 3 screws to fix the fan motor cover.
a
c
d
b
c
dd e f
a Ferrite core
b DC fan motor wiring harness

Table of Contents