Service Diagnosis
Si20 - 701_B

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin R60GVAL and is the answer not in the manual?

Summary

Service Diagnosis

Symptom-based Troubleshooting

2.2 Equipment does not Operate

Troubleshooting steps for when the equipment fails to operate.

2.3 Indoor Unit Fan Operates, but Compressor does not Operate

Diagnosing issues when the indoor fan runs but the compressor does not.

2.4 Cooling; Heating Operation Starts but Stops Immediately

Covers operations that start and then stop abruptly.

2.5 After Unit Shuts Down, It cannot be Restarted for a While

Explains issues with restarting the unit after it has shut down.

2.6 Equipment Operates but does not Provide Cooling

Troubleshooting for units that operate but do not cool effectively.

2.7 Equipment Operates but does not Provide Heating

Troubleshooting units that operate but do not provide heating.

2.9 Equipment Produces Loud Noise or Vibration

Addresses issues related to abnormal noise or vibration.

Troubleshooting by Remote Controller

3.1 Procedure of Self-diagnosis by Remote Controller

Steps for performing self-diagnosis using the remote controller.

3.2 Error Codes and Description (Indoor Unit)

List and description of indoor unit error codes.

3.3 Detailed Error Codes

Detailed explanations for various error codes.

3.4 A0 Error of External Protection Device

Troubleshooting for the A0 error related to external protection devices.

3.5 A1 Indoor Unit PCB Abnormality

Troubleshooting for A1 error, indicating an indoor unit PCB issue.

3.6 A3 Drain Water Level System Abnormality

Troubleshooting for the A3 error related to the drain water level system.

3.7 A6 Indoor Unit Fan Motor Abnormality

Covers the A6 error for indoor unit fan motor abnormalities.

3.8 A6 Fan Motor (M1 F) Lock, Overload

Troubleshooting for A6 error related to fan motor lock or overload.

3.9 A7 Swing Flap Motor Abnormality; Lock

Addresses the A7 error for swing flap motor abnormalities or lock.

3.10 A8 Abnormal Power Supply Voltage

Troubleshooting for the A8 error concerning abnormal power supply voltage.

3.11 A9 Electronic Expansion Valve Coil (Y1 E) Abnormality

Troubleshooting for the A9 error concerning the electronic expansion valve coil.

3.12 AF Drain System Abnormality

Troubleshooting for the AF error related to drain system abnormality.

3.13 AF Drain Level above Limit

Addresses the AF error when the drain level is above the limit.

3.14 AJ Capacity Setting Abnormality

Troubleshooting for the AJ error related to capacity setting abnormality.

3.15 C1 Transmission Error (between Indoor Unit PCB and Fan PCB)

Addresses C1 errors for transmission issues between indoor unit PCB and fan PCB.

3.16 C1 Transmission Error (between Indoor Unit PCB and Adaptor PCB)

Troubleshooting C1 errors for transmission between indoor unit PCB and adaptor PCB.

3.17 C4, C5, C9 Thermistor Abnormality

Troubleshooting for C4, C5, and C9 errors related to thermistor abnormalities.

3.18 C6 Defective Combination (between Indoor Unit PCB and Fan PCB)

Addresses C6 errors for defective combinations between indoor unit PCB and fan PCB.

3.19 CC Humidity Sensor System Abnormality

Troubleshooting for CC errors related to humidity sensor system abnormality.

3.20 CJ Remote Controller Thermistor Abnormality

Addresses CJ errors for remote controller thermistor abnormality.

3.21 E0 Actuation of Safety Device

Explains E0 error related to the actuation of safety devices.

3.22 E0 Activation of Outdoor Unit Protection Device

Troubleshooting for E0 error related to outdoor unit protection device activation.

3.23 E1 Outdoor Unit PCB Abnormality

Troubleshooting for E1 error indicating an outdoor unit PCB abnormality.

3.24 E3 High Pressure System Abnormality

Covers E3 error related to high pressure system abnormalities.

3.25 E3 Abnormally High Pressure Level (HPS)

Troubleshooting for E3 error indicating abnormally high pressure level (HPS).

3.26 E3 High Pressure Abnormality (HPS)

Addresses E3 error for high pressure abnormality (HPS).

3.27 E3 Actuation of High Pressure Switch

Explains E3 error related to actuation of high pressure switch.

3.28 E4 Low Pressure System Abnormality

Troubleshooting for E4 error related to low pressure system abnormality.

3.29 E4 Actuation of Pressure Sensor

Covers E4 error for actuation of pressure sensor.