Outdoor Fan / Fan Motor Si011360EC
4 Removal Procedure
5 Remove the screw, and
then the fan motor
fixing frame.
Be careful so as not to
damage the top part of the
outdoor heat exchanger fins.
When reassembling, put the
fan motor lead wire through
the back of the fan motor to
avoid any entanglement with
the outdoor fan.
When reassembling, fit the 2
lower hooks into the bottom
frame.
6 Unfasten the 2 hooks
and release the fan
motor lead wire.
7 Remove the 4 screws,
and then the fan motor.
Screw size: M4 × 16
Step Procedure Points
Fan motor fixing frame
(R19487)
(R15385)
(R3249)
Lead wire Outdoor fan
(R19009)
Hook
Fan motor
(R18992)