Engineering Data
Heat Recovery 60 Hz
Design Manual
RELQ-TATJA, 208 / 230 V
RELQ-TAYDA, 460 V
RELQ-TAYCA, 575 V
EDUS371705C-D ENGINEERING DATA VRV Aurora Series RELQ-TATJA / TAYDA / TAYCA HEAT RECOVERY 60 Hz DESIGN MANUAL
Question and Answer IconNeed help?

Do you have a question about the Daikin RELQ120TAYCA and is the answer not in the manual?

Daikin RELQ120TAYCA Specifications

General IconGeneral
ModelRELQ120TAYCA
CategoryHeating System
TypeAir Conditioner
Power Supply380-415 V
Power SourceElectric
Operating Temperature Range (Heating)-15°C to 24°C

Summary

Capacity Range

Specifications

RELQ-TATJA Specifications

Details electrical & mechanical specs for TATJA outdoor units.

RELQ-TAYDA Specifications

Provides electrical & mechanical specs for TAYDA outdoor units.

RELQ-TAYCA Specifications

Lists electrical & mechanical specs for TAYCA outdoor units.

Service Space

Foundation Drawing

Piping Diagrams

RELQ72TATJA/TAYDA/TAYCA Piping Diagrams

Illustrates the refrigerant piping circuit for specific outdoor units.

RELQ96-120TATJA/TAYDA/TAYCA Piping Diagrams

Shows refrigerant piping circuits for larger outdoor units.

Wiring Diagrams

RELQ72TATJA Wiring Diagram

Provides the electrical wiring diagram for the RELQ72TATJA outdoor unit.

RELQ96-120TATJA Wiring Diagram

Shows wiring diagram for RELQ96-120TATJA outdoor units.

RELQ72-120TAYDA Wiring Diagram

Illustrates the wiring diagram for RELQ72-120TAYDA outdoor units.

RELQ96-120TAYDA Wiring Diagram

Provides wiring diagram for RELQ96-120TAYDA outdoor units.

RELQ72-120TAYCA Wiring Diagram

Displays wiring diagram for RELQ72-120TAYCA outdoor units.

Field Wiring

Electrical Characteristics

RELQ72-120TATJA Electrical Data

Lists electrical data (MCA, MOP, RLA, FLA, SCCR) for TATJA models.

RELQ72-120TAYDA Electrical Data

Provides electrical data for TAYDA models.

RELQ72-120TAYCA Electrical Data

Details electrical data for TAYCA models.

Operation Limits

Low Ambient Cooling Enhancement

Selection Procedure

Selection Procedure Flowchart

Outlines the step-by-step process for selecting VRV systems.

Cautions and Service Precautions

Caution for Refrigerant Leaks

Refrigerant Leak Safety Introduction

Discusses R410A safety and maximum concentration levels.

Maximum Concentration Check Procedure

Explains how to calculate refrigerant density and check concentration.

Safety Devices Setting