Service
Manual
SiUS371901E
REYQ72-456XATJU
REYQ72-456XAYDU
REYQ72-432XAYCU
Heat Recovery 60 Hz

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin REYQ-XA and is the answer not in the manual?

Daikin REYQ-XA Specifications

General IconGeneral
BrandDaikin
ModelREYQ-XA
CategoryTemperature Controller
LanguageEnglish

Summary

Safety Cautions

Warnings and Cautions Regarding Safety of Workers

Safety guidelines for personnel performing maintenance and inspection.

Warnings and Cautions Regarding Safety of Users

Safety guidelines for end-users to prevent injury and equipment damage.

Used Icons

Model Names

Indoor Unit

Lists indoor unit models with their capacity ranges and specifications.

Outdoor Unit

Lists outdoor unit models (REYQ-XATJU, REYQ-XAYDU, REYQ-XAYCU) with capacities.

Air Treatment Equipment

Details of outdoor-air processing units and energy recovery ventilators.

Branch Selector Unit

Lists single and multi branch selector units with their specifications.

External Appearance

Indoor Unit

Illustrations and names of various indoor unit types.

Outdoor Unit

Illustrations of single, double, and triple outdoor units.

Air Treatment Equipment

Illustrations of outdoor-air processing units and energy recovery ventilators.

Branch Selector Unit

Illustrations of single and multi branch selector units.

Combination of Outdoor Units

REYQ-XATJU, REYQ-XAYDU, REYQ-XAYCU

Table detailing system capacity, number of units, modules, and piping kits.

Capacity Range

Connection Ratio

Explains the connection ratio formula and provides maximum connection ratios.

Outdoor Unit Combinations

Table showing combinations of outdoor units and connectable indoor units.

Limitation of Capacity Index for Heat Recovery

Specifies limitations for capacity index for single and multi branch selector units.

Specifications

REYQ-XATJU

Provides technical specifications for REYQ-XATJU, including cooling/heating capacity, dimensions, compressor details, and safety devices.

REYQ-XAYDU

Provides technical specifications for REYQ-XAYDU, including cooling/heating capacity, dimensions, and safety devices.

REYQ-XAYCU

Provides technical specifications for REYQ-XAYCU, including cooling/heating capacity, dimensions, and safety devices.

Refrigerant Circuit

Outdoor Unit

Lists and describes components within the outdoor unit's refrigerant circuit.

Indoor Unit

Details refrigerant circuit components within various indoor unit types and their functions.

Outdoor-Air Processing Unit

Describes refrigerant circuit components for outdoor-air processing units and their functions.

Branch Selector Unit

Details components and function of the branch selector unit.

Functional Parts Layout

REYQ72/96/120XATJU, REYQ72/96/120XAYDU, REYQ72/96/120XAYCU

Plane and front view illustrations of outdoor unit parts for specific models.

REYQ144/168XATJU, REYQ144/168XAYDU, REYQ144/168XAYCU

Plane and front view illustrations of outdoor unit parts for specific models.

Names and Functions

BRC1E73

Identifies and describes the buttons and LCD display of the BRC1E73 wired remote controller.

Wireless Remote Controller

Identifies and describes the buttons on the wireless remote controller.

Main/Sub Setting

BRC1E73

Details the situation and setting procedure for Main/Sub configuration of BRC1E73.

Address Setting for Wireless Remote Controller

Centralized Control Group No. Setting

BRC1E73

Details the procedure for setting group addresses for centralized control using BRC1E73.

Wireless Remote Controller

Provides instructions for setting group numbers for centralized control using wireless remote controllers.

Group No. Setting Example

Illustrates an example of group number settings for centralized control.

Service Settings Menu, Maintenance Menu

BRC1E73

Explains how to access service settings and maintenance menus using the BRC1E73 remote controller.

Function General

Outdoor Unit

Describes various control functions for the outdoor unit, including stop, standby, startup, basic, and protection controls.

Branch Selector Unit & Indoor Unit Operation Mode Detail

Details operation modes for branch selector units and indoor units in different scenarios.

Stop Control

Stop due to Error

Details how the system stops due to errors and refers to error code descriptions for diagnosis.

Standby Control

Restart Standby

Details the forced compressor stop for pressure equalization and residual control.

Crankcase Heater Control

Explains the control of the crankcase heater to prevent refrigerant melting in compressor oil.

Startup Control

Startup Control in Cooling

Details the startup control sequence for cooling operation, including frequency steps and conditions.

Startup Control in Heating

Details the startup control sequence for heating operation, including frequency steps and conditions.

Basic Control

Normal Control

Describes normal control operations for compressor, inverter fan, electronic expansion valves, and solenoid valves.

Compressor PI Control

Explains compressor capacity PI control for maintaining Te in cooling and Tc in heating.

Compressor Step Control

Details compressor operation steps based on information from Compressor PI Control.

Electronic Expansion Valve PI Control

Explains PI control for electronic expansion valves for condenser and evaporator operation.

Protection Control

High Pressure Protection Control

Explains high pressure protection control to prevent device activation and protect compressors.

Low Pressure Protection Control

Explains low pressure protection control to protect compressors from transient decrease of low pressure.

Discharge Pipe Protection Control

Details discharge pipe protection control to protect compressor internal temperature against errors or transient increases.

Compressor Body Protection Control

Explains compressor body protection control to protect internal temperature against errors or transient increases.

Inverter Protection Control

Covers inverter current protection and radiation fin temperature control.

Special Control

Pump Down Residual Control

Explains pump down residual control to recover refrigerant in the evaporator.

Oil Return Control

Describes oil return control to recover oil that flowed out from the compressor.

Defrost Control

Explains defrost control conducted to recover heating capacity.

Outdoor Unit Rotation

Details outdoor unit rotation to prevent compressor breakdown due to unbalanced oil level.

Cooling/Heating Mode Switching

Describes mode switching from cooling to heating or simultaneous operation.

Other Control

Backup Operation

Explains emergency operation when a compressor or outdoor unit fails.

Outline of Control (Indoor Unit)

Operation Flowchart

Flowcharts illustrating the operation logic for indoor units in cooling, heating, and fan modes.

Set Temperature and Control Temperature

Explains the relationship between remote controller set temperature and control target temperature.

Remote Controller Thermistor

Details temperature control using remote controller thermistors and suction air thermistors.

Thermostat Control

Explains thermostat control logic based on temperature differences and operation modes.

Drain Pump Control

Explains drain pump control during normal operation and float switch conditions.

Control of Electronic Expansion Valve

Explains superheating degree control in cooling and subcooling degree control in heating.

Freeze-Up Prevention

Explains freeze-up prevention control for indoor units by off cycling.

Hot Start Control (In Heating Only)

Describes hot start control to prevent cold air during heating startup.

Field Settings for Indoor Unit

Field Settings with Remote Controller

Instructions for configuring indoor unit settings using the remote controller and other methods.

List of Field Settings for Indoor Unit

Comprehensive list of field settings for indoor units, categorized by Mode No. and First Code No.

Details of Field Settings for Indoor Unit

Detailed explanations of field settings, including filter cleaning and thermistor selection.

Gas Furnace Set Up

List of Field Settings for Outdoor-Air Processing Unit

Setting of Operation Control Mode

Field Settings for Outdoor Unit

DIP Switch Setting Mounting a Spare PCB

Procedure for setting DIP switches on a spare PCB after replacement.

Monitoring Function and Field Settings

Describes how to define outdoor unit operations by changing field settings and monitoring parameters.

Overview of Setting Mode (Mode 2)

Provides an overview of available settings in Mode 2 accessed via outdoor unit PCB buttons.

Details of Setting Mode 2 (m2)

Detailed explanations of various settings available in Mode 2.

Cool/Heat Mode Changeover

Explains how to set Cool/Heat mode separately for each Branch Selector Unit.

Night-Time Low Noise Operation and Demand Operation

Details night-time low noise and demand operation settings via external contact or automatic control.

Night-Time Low Noise Operation

Explains how to set night-time low noise operation levels and start/stop times.

Demand Operation

Describes how to set demand operation levels for power consumption limitation.

Test Operation

Checks before Test Operation

Steps to perform before conducting a test operation.

Checkpoints

Checklist of items to verify before and during test operation.

Gas Furnace Test Operation

Procedure for performing a test operation of the gas furnace.

Symptom-based Troubleshooting

Indoor Unit Overall

Troubleshooting guide for common indoor unit issues like no start, immediate stop, or poor cooling/heating.

With Gas Furnace

Troubleshooting specific to systems with gas furnaces, including startup and switching issues.

Gas Furnace Lockout Reset

Procedure to clear gas furnace lockout errors via remote controller or furnace board.

With Optional Infrared Presence/Floor Sensor

Troubleshooting for issues related to optional infrared presence/floor sensors.

Troubleshooting with Remote Controller

Wired Remote Controller

Guides on checking and taking corrective action for errors displayed on the wired remote controller.

Wireless Remote Controller

Procedure for determining error codes and taking corrective action using the wireless remote controller.

Troubleshooting by Error Code

Error Codes and Descriptions

Lists error codes for indoor, outdoor, and branch selector units with descriptions and reference pages.

Outdoor Fan Motor Abnormality

Troubleshooting for outdoor fan motor abnormalities.

Electronic Expansion Valve Coil Abnormality, Dust Clogging

Troubleshooting for electronic expansion valve coil abnormalities and dust clogging.

Discharge Pipe Temperature Abnormality

Troubleshooting for discharge pipe temperature abnormalities.

Wet Alarm

Troubleshooting for wet alarm conditions related to liquid refrigerant return.

Refrigerant Overcharged

Troubleshooting for refrigerant overcharged conditions.

Harness Abnormality (between Outdoor Unit Main PCB and Inverter PCB)

Troubleshooting for harness abnormalities between outdoor unit main PCB and inverter PCB.

Power Supply Voltage Imbalance

Troubleshooting for power supply voltage imbalance conditions.

Compressor Startup Abnormality

Troubleshooting for abnormalities during compressor startup.

Transmission Error between Indoor Units and Outdoor Units, Open Phase in Power Supply Wiring

Troubleshooting transmission errors and open phase in power supply wiring.

Transmission Error between Remote Controller and Indoor Unit

Troubleshooting transmission errors between the remote controller and indoor unit.

Transmission Error between Outdoor Units

Troubleshooting transmission errors between outdoor units.

Improper Combination of Indoor, Branch Selector and Outdoor Units

Troubleshooting for issues caused by improper combinations of indoor, branch selector, and outdoor units.

Check

High Pressure Check

Fault tree analysis for diagnosing high pressure issues.

Low Pressure Check

Fault tree analysis for diagnosing low pressure issues.

Superheat Operation Check

Probes defective points related to superheat operation using fault tree analysis.

Power Transistor Check

Procedures for checking power transistors on REYQ-XA models using multimeter.

Thermistor Check

Lists thermistor types and their corresponding resistance values for troubleshooting.

Pressure Sensor Check

Details voltage measurement points for high and low pressure sensors.

Fan Motor Connector Check (Power Supply Cable)

Checks the power supply cable connections and resistance for fan motors.

Fan Motor Connector Check (Signal Cable)

Checks the signal cable connections and resistance for fan motors.

Electronic Expansion Valve Coil Check

Measures electronic expansion valve coil resistance and ensures it's within range.

Wiring Diagrams

Outdoor Unit

Wiring diagrams for outdoor units, covering different models like REYQ-XATJU.

Indoor Unit

Wiring diagrams for indoor units, including FXFQ, FXZQ, FXUQ, FXEQ, FXDQ, FXSQ, FXMQ models.

Air Treatment Equipment

Wiring diagrams for air treatment equipment such as outdoor-air processing units.

Branch Selector Unit

Wiring diagrams for single and multi branch selector units.