SiENBE04-808_A Field Settings
Trial Operation and Field Settings 290
Infrared Remote
Control
(1) Remove the cover and take it off.
(2) Cut the address setting jumper J4.
2.3 Standby Electricity Saving
Outline 20-42 Class Only
This function turns power supply OFF to the outdoor unit and sets the indoor unit into energy-
saving mode, thus reducing the power consumption of the air conditioner.
Detail For 20/25/35 class models, following procedure is required for turning ON the function.
1. Check that the main power supply is turned OFF. Turn OFF if it has not been turned OFF.
2. Remove the stop valve cover.
3. Disconnect the selective connector for standby electricity saving.
4. Turn ON the main power supply.
Caution Before connecting or disconnecting the selective connector for standby electricity saving, make
sure that the main power supply is turned OFF.
<ARC452 series> <ARC433 series>
Jumper
ADDRESS:J4
EXIST
1
CUT
2
(R12065)
Address
J4
EXIST
CUT
1
2
J4
(R6573)
1
2
3
1
2
3
(R11820)
Function OFF Function ON
The standby electricity saving function is turned OFF
before shipping.
SiENBE04-808_A.pdf 302 21/02/2011 13:20:25

Table of Contents

Other manuals for Daikin RKS20G2V1B9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin RKS20G2V1B9 and is the answer not in the manual?

Daikin RKS20G2V1B9 Specifications

General IconGeneral
BrandDaikin
ModelRKS20G2V1B9
CategoryHeat Pump
LanguageEnglish

Related product manuals