Strict cautions for keeping the system clean, dry, and tight with R-407C refrigerant.
Guidance for installing the indoor and outdoor units, including specific kits and components.
Instructions on how to lift and carry the unit safely to avoid damage or injury.
Securely fixing the unit to the foundation to prevent it from falling.
Procedures for properly disposing of drain water from the outdoor unit.
Required clearances around the unit for non-stacked installations.
Required clearances for units installed in stacked configurations.
Space requirements for units installed in multiple rows.
Details on pipe lengths and height differences for system configurations.
Important considerations for using existing piping and installing new piping.
Guidelines for handling refrigerants and using specific tools for R-407C.
Requirements for installing oil traps in riser piping to prevent oil return.
Best practices for brazing refrigerant pipes, including nitrogen purging.
Methods for installing field pipes in various directions.
Measures to prevent foreign objects from entering unit openings.
Proper handling and tightening of the valve cover.
Instructions on how to open and close the shut-off valves.
Procedures for handling the service port, including tightening the cover.
Precautions when connecting field piping, avoiding contact with components.
Measures to prevent condensation on the stop valve and piping.
Guidelines for processing flares and tightening torques to prevent leaks.
Specification for applying refrigerant oil to flares for R-407C.
Procedure for inspecting piping connections for gas leaks using nitrogen.
Steps for vacuuming the installation to remove air and moisture.
Detailed steps for conducting leak tests on refrigerant piping.
Guidelines for safely evacuating and charging refrigerant according to regulations.
Procedures for adding refrigerant based on piping length for pair and twin/triple systems.
Steps for charging refrigerant after a leak or for a full recharge.
Step-by-step guide for performing the pumping-down operation.
Safety guidelines and requirements for electrical wiring work.
Instructions on how to secure wiring with clamping materials and tie-wraps.
Essential checks before starting the test operation.
Steps to conduct the test run and initial operation checks.
Explains error codes displayed during test runs and their potential causes.
How to diagnose problems using error codes on the remote control.