Outer Panels Removal

Top Panel Removal

Remove the 4 screws and then the top panel.

Front Panel Removal

Unfasten right side hooks and detach the front panel after screw removal.

Discharge Grille Removal

Remove the securing screw and rotate the discharge grille to detach it.

Outdoor Fan and Fan Motor Removal

Disconnect Fan Motor Wiring

Pull terminals from capacitor and terminal board, release lead wire.

Remove Outdoor Fan Assembly

Remove the fan fixing frame nut and detach the outdoor fan.

Electrical Component Assembly Removal

Remove Side Panel and Covers

Remove the right side panel, stop valve cover, and wire fixture.

Disconnect Electrical Connections

Remove terminal board screws and disconnect connecting and power supply wires.

Sound Blanket and Capillary Tube Removal

Sound Blanket and Clamp Removal

Remove the sound blanket from the top and cut the 2 clamps.

Protection Net and Capillary Tube Removal

Remove protection net, putties, and heat/remove capillary tube.

Compressor Assembly Removal

Remove Compressor Nut and Cover

Remove the compressor nut and terminal cover.

Disconnect Compressor Lead Wires

Disconnect the compressor lead wires according to patterns.

Remove Compressor Mounting

Remove partition plate, compressor nuts, and disconnect pipes.