EasyManua.ls Logo

Daikin RQEQ180PY13 User Manual

Daikin RQEQ180PY13
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Series
System air conditioner
INSTALLATION MANUAL
English
Deutsch
Français
Español
Italiano
ΕλληνικÜ
Nederlands
Português
Рóссêий
Türkçe
Installation manual
VRV
III
System air conditioner
Installationsanleitung
VRV
III
System Klimaanlage
Manuel d’installation
Conditionneur d’air VRV
III
System
Manual de instalación
Sistema de acondicionador de aire VRV
III
Manuale di installazione
Condizionatore d’aria a sistema VRV
III
Εγχειρßδιο εγκατÜστασηò
Κλιìατιστικü ìε σýστηìα VRV
III
Installatiehandleiding
Airconditioner met VRV
III
Systeem
Manual de instalação
Ar condicionado VRV
III
System
Рóêоводство по монтажó
Кондиционер системы VRV
III
Montaj elkitabý
VRV
III
System Klima
MODELS
RQYQ140PY1
RQYQ180PY1
RQCYQ280PY1
RQCYQ360PY1
RQCYQ460PY1
RQCYQ500PY1
RQCYQ540PY1
RQEQ140PY13
RQEQ180PY13
RQEQ212PY13
RQCEQ280PY13
RQCEQ360PY13
RQCEQ460PY13
RQCEQ500PY13
RQCEQ540PY13
RQCEQ636PY13
RQCEQ712PY13
RQCEQ744PY13
RQCEQ816PY13
RQCEQ848PY13
00_CV_3P226891-14T.fm Page 1 Tuesday, September 16, 2014 9:50 AM
Question and Answer IconNeed help?

Do you have a question about the Daikin RQEQ180PY13 and is the answer not in the manual?

Daikin RQEQ180PY13 Specifications

General IconGeneral
ModelRQEQ180PY13
CategoryAir Conditioner
RefrigerantR32
Cooling Capacity5.0 kW
Heating Capacity1.6 ~ 20.0 kW
Power Source50 Hz
Indoor Unit Dimensions (W x H x D)1, 170 x 690 x 200 mm
Indoor Unit Dimensions (HxWxD)690 x 1, 170 x 200 mm
Weight (Indoor Unit)9.5 kg
Indoor Unit Weight9.5 kg
Weight (Outdoor Unit)32.0 kg
Outdoor Unit Weight32.0 kg

Summary

First Of All

Safety Precautions

Read these 'Safety precautions' carefully before installing air conditioning equipment.

Refrigerant Piping

Selection of Piping Material and Refrigerant Branching Kit

Guidelines for selecting piping material and refrigerant branching kits.

Pipe Connection

Procedures and precautions for connecting refrigerant pipes, including nitrogen purging.

Connecting the Refrigerant Piping

Instructions for bringing out pipes and precautions for knock-out holes.

Field Wiring

Power Circuit, Safety Device, and Cable Requirements

Requirements for power circuits, safety devices, and cable specifications for unit connection.

Transmission Wiring Connection Procedure

Procedure for connecting transmission wiring between units, with limitations specified.

Power Wiring Connection Procedure

Procedure for connecting power supply wiring to the terminal block securely.

Connecting Refrigerant Piping to Outdoor Units

Pipe Size Selection

Additional Refrigerant Charge and Check Operation

Procedure of Check Operation

Steps for performing check operation, including unit startup and refrigerant checks.

Check Operation

Detailed steps for performing check operation, including LED indicators and refrigerant charging.

LED Indications and Push-Button Functions

Remote Controller Indications and Error Codes

Error Codes (Defect Indications)

List and explanation of error codes displayed, indicating specific malfunctions or installation issues.

Test Run

Test Run

Procedures for operating the unit normally and checking its functionality after check operation.

Caution for Refrigerant Leaks

Related product manuals