Do you have a question about the Daikin RTD-10 and is the answer not in the manual?
Brand | Daikin |
---|---|
Model | RTD-10 |
Category | Recording Equipment |
Language | English |
Details unit control capabilities via resistance, voltage, BMS, heating interlock, duty/standby, Modbus, and custom configurations.
Covers installation via mounting pillars or screws, and orientation options for the RTD-10 unit.
Specifies the 15V to 24VDC power connection requirements from indoor unit PCBs for operation.
Details individual unit parameter control using resistance values for specific unit settings.
Explains P1,P2 network connections for Daikin units, supporting Master/Slave operation and remote controller integration.
Provides essential warnings regarding fault relay ratings and handling electrostatic sensitive devices.
Details individual unit parameter control using voltage signals for specific unit settings.
Configures operation in Master or Slave mode to prevent conflicting cooling/heating operations with secondary systems.
Configures Relay R1 as a Run signal or a Defrost signal based on SW1.3 setting.
Applies a setpoint limit (19-23 degrees) when SW1.4 is ON, affecting RC/Central Controller adjustments.
Configures remote controller button lock states via input S6, allowing various levels of control.
Enables duty/standby operation for up to 8 groups, suitable for IT/Telecoms applications with rotation.
Details Level 1 and Level 2 alarm outputs (R1, R2) for temperature and unit faults, forcing units to run.
Explains how inputs S5 and S6 override unit operation to force all units ON or OFF respectively.
Describes the use of a 10k NTC thermistor for monitoring space temperature and triggering alarms.
Covers networking, addressing, and DIP switch settings for Master/Slave duty/standby configurations.
Details the assignment of D-Bus addresses (SW1.5 to SW1.8) for creating control groups of up to 16 RTD-10 devices.
Specifies twisted pair cabling (DB, DA, GND) for RS485 D-Bus network installation, with length limitations.
Enables control via Modbus register commands when input S6 is open-circuit, allowing analogue holding register updates.
Details Modbus RTU Slave configuration parameters like Baud rate, Parity, and Stop bits.
Explains encoding of fault codes using a standard table for Daikin fault code generation.
Describes how input S6 affects Modbus control over keypad locking, with different behaviors for locked/unlocked states.
Allows VAM and VKM units to be switched on/off using the RTD-10 On/off input.
Details the meaning of LED indicators for Normal Operation, Error Conditions, and Unit Search status.
Explains the RTD-10's P1,P2 search mode upon power-up or communication loss.
Details electrical requirements including supply voltage, power consumption, and relay ratings.
Outlines operating and storage temperature ranges, and humidity requirements.
Provides dimensions, weight, casing material, and connector details.