EasyManua.ls Logo

Daikin RX25E2V1B - Removal of Four Way Valve; Electronic Expansion Valve Coil and Terminal Cover Removal; Compressor Lead Wire Disconnection

Daikin RX25E2V1B
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal of Four Way Valve Si00-772
18 Removal Procedure
6. Removal of Four Way Valve
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1
Pull out the electronic
expansion valve coil.
The cooling only models do
not have a four way valve
coil.
2
Remove the terminal
cover.
3
Disconnect the lead
wires of the
compressor.
(R7233)
Electronic
expansion
valve coil
(R7234)
Terminal cover
V
W
U
(R7235)
Red (U)
Yellow (V) Blue (W)