Ser vice
Manual
Inverter Pair
Wall Mounted Type C-Series
D-Series
[Applied Models]
zInverter Pair : Cooling Only
zInverter Pair : Heat Pump
SiENBE04-401A

Table of Contents

Questions and Answers

  • K
    Kelly PottsAug 14, 2025
    Why is my Daikin RXH35CAVMB Air Conditioner outdoor unit leaking water?
    • C
      Corey KnightAug 14, 2025
      In HEAT mode, the frost on the outdoor unit melts into water or steam during defrost operation. In COOL or DRY mode, moisture in the air condenses into water on the cool surface of the outdoor unit piping and drips.
  • C
    Carrie HuffAug 17, 2025
    Why does my Daikin Air Conditioner smell?
    • L
      Lori PatelAug 17, 2025
      The Daikin Air Conditioner may emit odors because smells from the room, furniture, or cigarettes have been absorbed into the unit and are being discharged with the airflow. It is recommended to have the indoor unit cleaned by a technician. Consult the service shop where you bought the air conditioner.
  • B
    Brett HallAug 21, 2025
    What to do if my Daikin Air Conditioner heating stops suddenly?
    • J
      justindeanAug 21, 2025
      The system is likely removing frost from the outdoor unit. You should wait for about 3 to 8 minutes.
  • A
    Amanda AllenAug 25, 2025
    Why doesn't hot air come out immediately from my Daikin RXH35CAVMB when heating?
    • P
      Philip HartmanAug 25, 2025
      You should wait for 1 to 4 minutes. The system is designed to start discharging air only after it has reached a certain temperature.
  • K
    kimlaurenAug 28, 2025
    Why my Daikin RXH35CAVMB Air Conditioner does not start immediately?
    • P
      pwigginsAug 28, 2025
      If the ON/OFF button was pressed soon after operation was stopped, or if the mode was reselected, you should wait for about 3 minutes.
  • C
    Claire BarkerSep 1, 2025
    What to do if my Daikin RXH35CAVMB operation stopped suddenly?
    • M
      Mark RichardsonSep 1, 2025
      For system protection, the air conditioner may stop operating due to a sudden large voltage fluctuation. It will automatically resume operation in about 3 minutes.
  • P
    Penny LewisSep 5, 2025
    Why is the Daikin Air Conditioner outdoor fan running when it's off?
    • G
      Gary GarciaSep 5, 2025
      After operation is stopped, the outdoor fan may continue rotating for another 60 seconds for system protection. Also, when the outdoor temperature is very high, the outdoor fan might start rotating for system protection even when the air conditioner is not in operation.
  • J
    Jessica HarveySep 9, 2025
    Why does mist come out of my Daikin RXH35CAVMB?
    • J
      Joseph HooperSep 9, 2025
      This happens when the air in the room is cooled into mist by the cold air flow during cooling operation.

Summary

Part 1 List of Functions

Part 2 Specifications

1. Specifications

Provides detailed technical specifications for the air conditioning units.

1.1 Cooling Only

Specifies technical details for cooling-only models.

1.2 Heat Pump

Specifies technical details for heat pump models.

Part 3 Printed Circuit Board Connector Wiring Diagram

Part 4 Function and Control

1. Main Functions

Explains core operational functions like frequency principles and airflow.

3. Control Specification

Outlines control specifications for various operating modes and conditions.

Part 5 System Configuration

2.1 Safety precautions

Essential safety guidelines for handling and operating the unit.

2.12 Troubleshooting

Provides solutions for common operational problems and malfunctions.

Part 6 Service Diagnosis

2. Problem Symptoms and Measures

Lists common symptoms and their corresponding troubleshooting steps.

4. Troubleshooting

Detailed troubleshooting guide for various error codes and malfunctions.

4.1 Error Codes and Description

A table of error codes and their meanings for diagnosis.

4.2 Indoor Unit PCB Abnormality

Troubleshooting steps for indoor unit PCB issues.

4.3 Freeze-up Protection Control or High Pressure Control

Diagnosing and resolving freeze-up or high-pressure issues.

4.4 Fan Motor (AC Motor) or Related Abnormality

Troubleshooting fan motor problems.

4.5 Thermistor or Related Abnormality (Indoor Unit)

Diagnosing indoor unit thermistor issues.

4.6 Signal Transmission Error (between Indoor and Outdoor Unit)

Troubleshooting communication errors between units.

4.7 OL Activation (Compressor Overload)

Addressing compressor overload issues.

4.8 Compressor Lock

Steps for diagnosing and resolving compressor lock errors.

4.9 DC Fan Lock

Troubleshooting DC fan lock errors.

4.10 Input Over Current Detection

Diagnosing and resolving input over-current issues.

4.11 Four Way Valve Abnormality

Troubleshooting four-way valve problems.

4.12 Discharge Pipe Temperature Control

Addressing discharge pipe temperature control issues.

4.13 High Pressure Control in Cooling

Diagnosing high-pressure issues during cooling.

4.14 Position Sensor Abnormality

Troubleshooting position sensor errors.

4.15 DC Voltage; Current Sensor Abnormality

Diagnosing DC voltage/current sensor abnormalities.

4.16 Thermistor or Related Abnormality (Outdoor Unit)

Troubleshooting outdoor unit thermistor issues.

4.17 Electrical Box Temperature Rise

Addressing electrical box temperature rise issues.

4.18 Radiation Fin Temperature Rise

Diagnosing radiation fin temperature rise.

4.19 Output Over Current Detection

Troubleshooting output over-current detection.

4.20 Insufficient Gas

Diagnosing and resolving insufficient gas conditions.

4.21 Over-voltage Detection

Troubleshooting over-voltage detection errors.

Part 7 Removal Procedure

Daikin RXH35CAVMB Specifications

General IconGeneral
CategoryAir Conditioner
Capacity3.5 kW
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
RefrigerantR32
Power Supply220-240 V, 50 Hz