REMOVAL
PROCEDURE
SERVICE MANUAL
5.0/6.0/7.1/8.0 kW Class
18000/24000/28000 Btu/h Class
Outdoor Unit
Inverter / Hybrid
Pair Type
Si00-876
Question and Answer IconNeed help?

Do you have a question about the Daikin RXS50B2VMB and is the answer not in the manual?

Daikin RXS50B2VMB Specifications

General IconGeneral
CategoryAir Conditioner
ModelRXS50B2VMB
TypeSplit System
Cooling Capacity5.0 kW
RefrigerantR32
Energy Efficiency Ratio (EER)3.5
Energy Efficiency Ratio (Cooling)3.5
Power Supply220-240 V, 50 Hz

Summary

Removal of Outer Panels

Outer Panel and Discharge Grille Removal

Steps to detach the top panel and discharge grille from the outdoor unit casing.

Stop Valve Cover Removal Procedure

Guide to safely remove the stop valve cover by unscrewing and releasing its hooks.

Outdoor Fan and Fan Motor Removal

Electrical Box Cover Removal Steps

Procedure for accessing internal components by removing the electrical box cover.

Fan Motor Disassembly Guide

Instructions for disconnecting the fan motor connector and safely removing the fan motor.

PCB and Electrical Box Removal

Accessing Internal Components via Side Panel

Steps to remove the right side panel to gain access to PCBs and electrical components.

Service Monitor PCB Extraction Process

Detailed steps for removing the service monitor PCB, including harness and connector detachment.

Main PCB Extraction Process

Instructions for removing the main PCB, involving hook release, terminal board access, and harness disconnection.

Reactor Component Removal

Partition Plate and Reactor Disassembly

Guide to removing the reactor by detaching the partition plate and associated fittings.

Sound Blanket Removal

Thermistor Assembly Removal Guide

Procedure for detaching thermistor assemblies, involving clip release and clamp cutting.

Sound Blanket Detachment Steps

Instructions for carefully removing various sound insulation blankets from the unit.

Four Way Valve Component Removal

Four Way Valve Disconnection Guide

Steps to safely disconnect the four way valve by heating brazed connections.

Electronic Expansion Valve Removal

Electronic Expansion Valve Detachment

Procedure to remove the electronic expansion valve by heating and disconnecting its parts.

Compressor Component Removal

Compressor Terminal Cover and Wire Disconnection

Steps to access and disconnect the compressor's electrical connections safely.

Compressor Brazing and Final Removal

Procedure for heating and disconnecting brazed pipes and lifting the compressor unit.