REMOVAL
PROCEDURE
SERVICE MANUAL
Outdoor Unit
Inverter / Hybrid
Pair Type
4.2/5.0/6.0/7.1 kW Class
Si00-875
Question and Answer IconNeed help?

Do you have a question about the Daikin RXS50FVMA and is the answer not in the manual?

Daikin RXS50FVMA Specifications

General IconGeneral
BrandDaikin
ModelRXS50FVMA
CategoryAir Conditioner
LanguageEnglish

Summary

1. Removal of Outer Panels

Top Panel and Discharge Grille Removal

Procedure to remove the top panel and discharge grille by unscrewing and detaching.

Front Panel Removal

Steps to remove the front panel by unscrewing and unfastening hooks.

Stop Valve Cover Removal

Procedure to remove the stop valve cover by unscrewing and unfastening hooks.

2. Removal of Outdoor Fan / Fan Motor

Fan Motor Removal

Steps to disconnect the fan motor, release lead wires, and remove the fan nut.

3. Removal of Electrical Box

4. Removal of PCBs

Service Monitor PCB Removal

Disconnect connectors and detach clamps to remove the service monitor PCB.

Main PCB Removal

Remove screws and hooks to detach and lift out the main PCB.

5. Removal of Sound Blankets / Thermistors

Sound Blanket Removal

Procedure to remove sound blankets from various locations like top, back, outer, and inner sections.

Thermistor Removal

Procedure to release and remove discharge pipe and outdoor heat exchanger thermistors.

6. Removal of Four Way Valve

7. Removal of Electronic Expansion Valve

8. Removal of Compressor