Service
Manual
SiUS341615E
RXYQ72-408TAYDU
RXYQ72-408TATJU
Heat Pump 60 Hz

Table of Contents

Other manuals for Daikin RXYQ96TATJU

Questions and Answers:

Daikin RXYQ96TATJU Specifications

General IconGeneral
ModelRXYQ96TATJU
CategoryHeat Pump
Cooling Capacity (kW)28.1 kW
Power Supply3 Phase, 400V, 50Hz
RefrigerantR-32
Energy Efficiency Ratio (EER)3.2
Coefficient of Performance (COP)4.0
Cooling Capacity96000 BTU/hr
Heating Capacity108000 BTU/hr
Dimensions (Outdoor Unit)1200 x 900 x 2000 mm
Weight (Outdoor Unit)1, 190 lbs (540 kg)

Summary

Part 2 Refrigerant Circuit

Refrigerant Flow for Each Operation Mode

Diagrams illustrating refrigerant flow during cooling and heating operations for various models.

Cooling Operation Refrigerant Flow

Detailed refrigerant flow path during normal cooling operation for RXYQ72TAYDU/TATJU models.

Part 4 Functions and Control

Protection Control

Details on protection mechanisms like high and low pressure, discharge pipe, and inverter protection.

High Pressure Protection Control

Describes control actions taken when high pressure exceeds normal limits to protect compressors.

Part 5 Field Settings

Test Operation

Procedures for performing test operations, including pre-test checks and checkpoints.

Checks before Test Operation

Essential pre-operation checks, including voltage, stop valve status, and pipe insulation.

Part 6 Service Diagnosis

Symptom-based Troubleshooting

Troubleshooting guide based on observed system symptoms like no start, immediate stop, or poor cooling/heating.

Indoor Unit Overall Troubleshooting

Addresses common issues with indoor units such as failure to start, immediate stops, or inefficient operation.

Error Codes and Descriptions

List of error codes for indoor and outdoor units, their descriptions, and corresponding reference pages.

Troubleshooting by Error Code

Detailed troubleshooting steps for specific error codes, including causes and corrective actions.

External Protection Device Abnormality

Troubleshooting steps for errors related to external protection devices and their connections.

Fan Motor Lock, Overload

Troubleshooting for fan motor issues like lock, overload, or abnormal revolutions.

Low Indoor Airflow

Diagnosis and corrective actions for low airflow issues in indoor units, possibly due to obstructions or motor faults.

Thermistor Abnormality

Steps for diagnosing and resolving errors related to thermistor disconnections or short circuits.

Transmission Error between Outdoor Units

Troubleshooting for communication errors occurring between multiple outdoor units in a system.

U7-01 Transmission Error

Specific troubleshooting flowchart for U7-01 error related to transmission issues with external control adaptors.

Improper Combination of Indoor Unit and Outdoor Unit

Troubleshooting steps for errors arising from incorrect unit combinations or PCB settings.

UA-17 Excess Indoor Units

Diagnosis for UA-17 error, focusing on issues related to the number of connected indoor units.