System air conditioner
OPERATION MANUAL
MODEL
RXYQ72PYDN
RXYQ96PYDN
RXYQ120PYDN
RXYQ144PYDN
RXYQ168PYDN
RXYQ192PYDN
RXYQ216PYDN
RXYQ240PYDN
RXYQ72PTJU
RXYQ96PTJU
RXYQ120PTJU
RXYQ144PTJU
RXYQ168PTJU
RXYQ192PTJU
RXYQ216PTJU
RXYQ240PTJU
Read these instructions carefully before installation.
Keep this manual in a handy place for future reference.
This manual should be left with the equipment owner.
English
Français
Español
REYQ72PYDN
REYQ96PYDN
REYQ120PYDN
REYQ144PYDN
REYQ168PYDN
REYQ192PYDN
REYQ216PYDN
REYQ240PYDN
REYQ72PTJU
REYQ96PTJU
REYQ120PTJU
REYQ144PTJU
REYQ168PTJU
REYQ192PTJU
REYQ216PTJU
REYQ240PTJU
00_CV_3P215731-1D.fm Page 1 Wednesday, February 6, 2008 11:34 AM

Questions and Answers

  • T
    Timothy TorresAug 11, 2025
    Why is my Daikin Air Conditioner not cooling or heating enough?
    • B
      Barbara HoweAug 11, 2025
      If your Daikin Air Conditioner isn't cooling or heating sufficiently, several factors could be at play. First, ensure that neither the air inlet nor outlet of the indoor or outdoor unit is obstructed; remove any blockages to improve ventilation. Next, verify if the remote controller indicates it's time to clean the air filter. Also, review your temperature and fan speed settings on the remote. Other potential issues include open doors or windows, too many people in the room, excessive heat sources, direct sunlight, or an improper airflow angle. Check each of these elements to optimize performance.
  • T
    Tammy DyerAug 18, 2025
    Why does my Daikin Air Conditioner stop soon after starting?
    • D
      Debra CarneyAug 19, 2025
      If your Daikin Air Conditioner stops shortly after starting, examine the outdoor and indoor units to ensure that the air inlets and outlets are free from obstructions. Remove any obstacles to ensure proper ventilation. Also, check the remote controller display for an indication to clean the air filter and proceed to clean the air filter.
  • P
    Phillip RodriguezAug 26, 2025
    What to do if my Daikin Air Conditioner system does not operate at all?
    • B
      Bryce HallAug 27, 2025
      If your Daikin Air Conditioner system isn't starting, first check for a power failure and wait for the power to be restored. If there is no power failure, check if a fuse has blown and turn off the power supply. Another potential issue is a blown breaker.
  • C
    Cynthia FriedmanSep 2, 2025
    What to do if my Daikin Air Conditioner displays 'TEST' and a malfunction code?
    • T
      Troy CarrollSep 3, 2025
      If the display on your Daikin Air Conditioner shows 'TEST', the unit number, and the TEST operation lamp are flashing, and a malfunction code appears, you should notify your Daikin dealer and report the malfunction code.

Daikin RXYQ96PYDN Specifications

General IconGeneral
ModelRXYQ96PYDN
CategoryHeat Pump
BrandDaikin
Heating Capacity (kW)30.0
Max Number of Indoor Units16
Power Supply380-415V, 50Hz, 3-Phase
RefrigerantR410A
Operating Temperature Range (Cooling)-5°C to 46°C
Operating Temperature Range (Heating)-20°C to 15.5°C

Related product manuals