Installer and user reference guide
VRV 5-S system air conditioner
RXYSA4A7V1B
RXYSA5A7V1B
RXYSA6A7V1B
RXYSA4A7Y1B
RXYSA5A7Y1B
RXYSA6A7Y1B

Table of Contents

Other manuals for Daikin RXYSA4A7Y1B

Questions and Answers:

Daikin RXYSA4A7Y1B Specifications

General IconGeneral
ModelRXYSA4A7Y1B
CategoryAir Conditioner
Energy Efficiency Ratio (Cooling)3.5
Energy Efficiency Ratio (Heating)3.8
RefrigerantR32
Power Supply220-240 V, 50 Hz

Summary

2 General safety precautions

2.2 For the installer

Provides safety instructions specifically for installers.

2.2.2 Installation site

Specifies requirements for the unit's installation location.

2.2.3 Refrigerant

Information and precautions regarding refrigerant handling.

2.2.6 Electrical

Critical safety instructions for electrical installation and wiring.

3 Specific installer safety instructions

Installation site

Specific safety requirements for selecting the installation site.

Connecting the refrigerant piping

Safety precautions for connecting refrigerant piping.

Charging refrigerant

Safety instructions and precautions for charging refrigerant.

Electrical installation

Specific safety instructions for electrical wiring and installation.

Commissioning

Safety precautions to be taken during the commissioning process.

Troubleshooting

Safety precautions to be observed when troubleshooting the system.

3.1 Instructions for equipment using R32 refrigerant

Specific safety instructions for equipment using R32 refrigerant.

3.1.1 Installation space requirements

Details on required installation space and clearances.

3.1.2 System layout requirements

Guidelines for proper system layout and piping.

3.1.3 To determine the charge limitations

Procedure to determine maximum allowable refrigerant charge.

4 User safety instructions

4.2 Instructions for safe operation

Guidelines and precautions for safe operation of the unit.

7 Before operation

8 Operation

8.2 Operating the system

Instructions on how to operate the system and its various modes.

8.2.2 About cooling, heating, fan only, and automatic operation

Details on different operating modes like cooling, heating, and fan.

8.2.4 To operate the system (WITHOUT cool/heat changeover remote control switch)

Step-by-step guide for operating the system without a changeover switch.

8.2.5 To operate the system (WITH cool/heat changeover remote control switch)

Step-by-step guide for operating the system with a changeover switch.

8.3.2 To use the dry program (WITHOUT cool/heat changeover remote control switch)

Procedure to use the dry program without a changeover switch.

9 Energy saving and optimum operation

10 Maintenance and service

11 Troubleshooting

11.1 Error codes: Overview

List and explanation of error codes displayed by the system.

17 Unit installation

18 Piping installation

18.2 Connecting the refrigerant piping

Procedures and precautions for connecting refrigerant piping.

18.2.2 Precautions when connecting the refrigerant piping

Essential safety precautions to observe during piping connection.

18.3 Checking the refrigerant piping

Procedures for checking the refrigerant piping for leaks and dryness.

18.3.4 To perform a leak test

Detailed procedure for performing leak tests on the piping.

18.3.5 To perform vacuum drying

Procedure for vacuum drying the refrigerant piping system.

19 Charging refrigerant

19.3 Precautions when charging refrigerant

Essential precautions and safety measures for refrigerant charging.

19.4 To determine the additional refrigerant amount

Method for calculating the amount of additional refrigerant needed.

19.5 To charge refrigerant

Step-by-step guide for charging refrigerant into the system.

19.6 Error codes when charging refrigerant

List of error codes that may occur during refrigerant charging.

19.8 To check for refrigerant leaks after charging

Procedure for checking for refrigerant leaks after the charging process.

20 Electrical installation

20.1.1 Precautions when connecting the electrical wiring

Safety precautions to be followed during electrical wiring connection.

20.2 To connect the electrical wiring to the outdoor unit

Step-by-step guide for connecting wiring to the outdoor unit.

21 Finishing the outdoor unit installation

22 Configuration

22.2.8 Mode 2: Field settings

Detailed explanation of various field settings available in mode 2.

22.3 Energy saving and optimum operation

How to configure settings for energy saving and optimal performance.

23 Commissioning

23.1 Precautions when commissioning

Safety precautions and warnings before starting commissioning.

23.2 Checklist before commissioning

A comprehensive checklist of items to verify before commissioning.

23.3 Checklist during commissioning

A checklist of tasks to perform during the commissioning process.

23.5 To perform a test run (7-segments display)

Step-by-step guide for performing a test run using the 7-segment display.

23.6 Correcting after abnormal completion of the test run

Procedures for addressing and correcting abnormalities found during test runs.

24 Hand-over to the user

25 Maintenance and service

25.2 Maintenance safety precautions

Essential safety precautions to follow during maintenance work.

25.2.1 To prevent electrical hazards

Specific measures to prevent electrical hazards during maintenance.

25.4.2 To recover refrigerant

Procedure for recovering refrigerant using a recovery unit.

26 Troubleshooting

26.2 Precautions when troubleshooting

Safety precautions to observe while troubleshooting the system.

26.3 Solving problems based on error codes

Guidance on resolving issues based on displayed error codes.

26.3.1 Error codes: Overview

A list and explanation of error codes and their causes.

26.4 Refrigerant leak detection system

Information on the refrigerant leak detection system and its operation.