Model | RXYSQ5P8Y1B |
---|---|
Category | Air Conditioner |
Cooling Capacity | 14.0 kW |
Heating Capacity | 16.0 kW |
Cooling Capacity (kW) | 14.0 |
Power Source | Electric |
Power Supply | 380-415V / 50Hz / 3Ph |
Refrigerant | R410A |
Operating Temperature (Cooling) | -5°C to 46°C |
Operating Temperature (Heating) | -15°C to 15.5°C |
Describes the layout of BP unit, main/branch piping, and power supply.
Details compatible indoor unit combinations with outdoor units based on capacity.
Lists standard accessories included with the unit for installation.
Lists optional parts required for installation of outdoor units.
Refers to the Engineering Data Book for complete specifications.
Strict cautions for keeping the R410A system clean, dry, and tight.
Instructions for installing indoor units, BP units, and handling components.
Guidance on how to handle and carry the unit safely.
Describes how to secure the unit to prevent it from falling over.
Instructions for removing the transportation stay from the compressor.
Guidelines for selecting appropriate piping material and thickness for refrigerant lines.
Precautions and procedures for brazing refrigerant piping, including nitrogen blow.
Guidelines for making secure flare connections for refrigerant pipes.
Instructions to prevent foreign objects from entering the unit during installation.
Precautions when handling the stop valves for refrigerant lines.
Step-by-step guide on opening and closing stop valves.
Selection criteria for refrigerant branch kits for VRV indoor units.
Details on selecting pipe sizes for VRV indoor unit refrigerant connections.
Important notes on selecting connection pipes for VRV systems.
Step-by-step guide for adding refrigerant using the automatic charging function.
Lists and describes internal components and their designations for wiring.
Safety precautions to be taken before performing maintenance or service on the unit.
Instructions for operating switches for field settings using an insulated stick.
Identifies the location of DIP switches, LEDs, and buttons on the outdoor unit PCB.
Explains the function of the push button switches on the outdoor unit PCB.
Procedure for changing the unit's operation mode settings.
Lists error codes and their remedial actions for troubleshooting.
Procedures for checking normal operation with wired remote controllers.
Procedures for checking normal operation with wireless remote controllers.
Procedure for vacuuming the system, typically for repair purposes.
Method for recovering refrigerant using a specialized reclaimer.
Introduction to refrigerant leak precautions and R410A safety.
Explains maximum allowable refrigerant concentration based on room volume.