Service Diagnosis
Si20 - 701_B

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin RY125FUTAL and is the answer not in the manual?

Daikin RY125FUTAL Specifications

General IconGeneral
ModelRY125FUTAL
TypeInverter
Cooling Capacity12.5 kW
Heating Capacity14.0 kW
Energy Efficiency Ratio (EER)3.21
RefrigerantR32
CategoryAir Conditioner
Power Supply380-415V, 3 Ph, 50Hz
Sound Pressure Level (Outdoor)52 dBA

Summary

2. Symptom-based Troubleshooting

2.1 Overview

Provides a summary of symptoms and corresponding troubleshooting measures.

2.2 Equipment does not Operate

Lists supposed causes for equipment failure to operate and troubleshooting steps.

2.4 Cooling / Heating Operation Starts but Stops Immediately

Outlines troubleshooting steps for units that start and then stop operation immediately.

2.6 Equipment Operates but does not Provide Cooling

Details troubleshooting for scenarios where the unit operates but does not provide cooling.

3. Troubleshooting by Remote Controller

3.1 Procedure of Self-diagnosis by Remote Controller

Explains how to perform self-diagnosis using the remote controller and interpret error codes.

3.2 Error Codes and Description

Lists error codes with descriptions and their applicability to different model names.

3.3 Detailed Error Codes

Provides detailed descriptions and diagnostic steps for specific error codes for indoor and outdoor units.

3.5 A1 Indoor Unit PCB Abnormality

Explains troubleshooting for abnormality detected in the indoor unit PCB, possibly due to noise or external factors.

3.6 A3 Drain Water Level System Abnormality

Covers troubleshooting for drain water level abnormalities, including issues with the drain pump and float switch.

3.23 E1 Outdoor Unit PCB Abnormality

Guides on troubleshooting abnormalities detected in the outdoor unit PCB.

3.24 E3 High Pressure System Abnormality

Addresses high pressure system abnormalities, including the high pressure switch.

3.28 E4 Low Pressure System Abnormality

Covers troubleshooting for low pressure system abnormalities, including the low pressure sensor.

3.32 E5 Compressor Motor Lock

Provides troubleshooting steps for compressor motor lock issues, often related to inverter PCB or wiring.

3.40 F6 Refrigerant Overcharged

Explains how to diagnose and address issues related to excessive refrigerant charging.

3.72 LC Transmission Error Between Inverter and Control PCB

Explains troubleshooting for transmission errors between the inverter and control PCBs.

3.83 U0 Refrigerant Shortage

Explains troubleshooting for refrigerant shortage and related piping issues.

3.92 U4 or UF Transmission Error (Between Indoor Unit and Outdoor Unit)

Details troubleshooting for transmission errors between indoor and outdoor units due to wiring or PCB issues.

3.105 UF Mis-connection of Field Wiring

Addresses issues related to mis-connected field wiring.