EasyManua.ls Logo

Daikin RYMQ12T7Y1B - User Manual

Daikin RYMQ12T7Y1B
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installer and user reference guide
VRV IV system air conditioner
English
Installer and user
reference guide
VRV IV system air conditioner
RYYQ8T7Y1B*
RYYQ10T7Y1B*
RYYQ12T7Y1B*
RYYQ14T7Y1B*
RYYQ16T7Y1B*
RYYQ18T7Y1B*
RYYQ20T7Y1B*
   
RYMQ8T7Y1B*
RYMQ10T7Y1B*
RYMQ12T7Y1B*
RYMQ14T7Y1B*
RYMQ16T7Y1B*
RYMQ18T7Y1B*
RYMQ20T7Y1B*
   
RXYQ8T7Y1B*
RXYQ10T7Y1B*
RXYQ12T7Y1B*
RXYQ14T7Y1B*
RXYQ16T7Y1B*
RXYQ18T7Y1B*
RXYQ20T7Y1B*

Table of Contents

Other manuals for Daikin RYMQ12T7Y1B

Questions and Answers

Summary

General Safety Precautions

About the Documentation

Provides information about warnings, symbols, and the overall documentation structure.

For the User

Details on operating the unit, safety precautions, and user notices.

For the Installer

Instructions for installers, including general guidelines and site selection.

About the Documentation

About this Document

Describes the document set and target audience for the VRV IV system.

About the Box

Overview: About the Box

Details what to do after the outdoor unit box is delivered on-site.

To Unpack the Outdoor Unit

Instructions for safely removing the outdoor unit from its packing material.

About the Units and Options

Overview: About the Units and Options

Information on unit identification, system layout, and indoor unit combinations.

About the Outdoor Unit

System Layout

Combining Units and Options

About Combining Units and Options

Guidance on consulting technical data for system setup and allowed combinations.

Possible Combinations of Indoor Units

Provides an overview of allowed combinations between indoor and outdoor units.

Preparation

Overview: Preparation

Outlines tasks required before on-site work, including site, piping, and wiring preparation.

Preparing Installation Site

Installation Site Requirements of the Outdoor Unit

Details space, ventilation, and level requirements for outdoor unit installation.

Preparing Refrigerant Piping

Refrigerant Piping Requirements

Cautions for keeping the system clean, dry, and tight with R410A refrigerant.

To Select the Piping Size

Guidance on determining proper pipe size based on capacity and unit type.

To Select Refrigerant Branch Kits

Piping Length: VRV DX and Hydrobox

Requirements in Case of FXTQ Indoor Units

Multiple Outdoor Units: Possible Layouts

Preparing Electrical Wiring

About Electrical Compliance

Ensures electrical work complies with EN/IEC standards for safety and performance.

Safety Device Requirements

Details required safety devices like main switches, fuses, and earth leakage protectors.

Installation

Opening the Units

Instructions for accessing internal components by opening the outdoor unit panels.

Connecting the Refrigerant Piping

Precautions when Connecting Refrigerant Piping

Emphasizes clean, dry, and tight piping installation, and pressure limits.

About Connecting the Refrigerant Piping

Outlines the process of connecting refrigerant piping after unit mounting.

To Route the Refrigerant Piping

To Connect the Refrigerant Piping to the Outdoor Unit

Multiple Outdoor Units: Knockout Holes

To Braze the Pipe End

Using the Stop Valve and Service Port

Checking the Refrigerant Piping

About Checking the Refrigerant Piping

Describes when to perform leak test and vacuum drying based on power status.

Leak Test and Vacuum Drying

Details the process of checking for leaks and removing moisture from piping.

To Perform a Leak Test

To Perform Vacuum Drying

To Insulate the Refrigerant Piping

Charging Refrigerant

Precautions When Charging Refrigerant

Safety warnings for refrigerant type, handling, and environmental impact.

About Charging Refrigerant

Explains the two methods for charging additional refrigerant after vacuum drying.

To Determine the Additional Refrigerant Amount

Guidance on calculating the extra refrigerant needed based on system configuration.

To Charge Refrigerant: Flow chart

Step 6 a: To Automatically Charge Refrigerant

Step 6 b: To Manually Charge Refrigerant

Error codes when charging refrigerant

Connecting the Electrical Wiring

Precautions when Connecting Electrical Wiring

Electrical safety warnings for licensed installers and compliance with legislation.

Field Wiring: Overview

About the Electrical Wiring

Guidelines when Knocking Out Knockout Holes

To Route and Fix the Transmission Wiring

To Connect the Transmission Wiring

To Finish the Transmission Wiring

To Route and Fix the Power Supply

To Connect the Power Supply

Configuration

Overview: Configuration

Guide to configuring the system after installation, covering field settings and operation.

Making Field Settings

About Making Field Settings

Explains manual input via PCB push buttons and reading 7-segment displays.

Field Setting Components

Identifies locations of 7-segment displays, buttons, and DIP switches on the PCB.

To Access Mode 1 or 2

To Use Mode 1

To Use Mode 2

Mode 1: Monitoring Settings

Mode 2: Field Settings

Energy Saving and Optimum Operation

Available Main Operation Methods

Explains basic, automatic, and hi-sensible/economic operation modes for energy efficiency.

Available Comfort Settings

Commissioning

Overview: Commissioning

Guides the installer to verify correct operation and commission the system after setup.

Using the Leak Detection Function

About Automatic Leak Detection

Details the activation and parameters for automatic leak detection.

To Manually Perform a Leak Detection

Step-by-step procedure to manually activate and execute leak detection.

To Perform a Test Run

Correcting After Abnormal Completion of the Test Run

Operating the Unit

Maintenance and Service

Maintenance and Service

Overview of maintenance tasks and safety precautions for service personnel.

Maintenance Safety Precautions

Critical safety warnings for electrical hazards and electrostatic discharge during service.

To Prevent Electrical Hazards

Detailed steps to prevent electrical hazards when servicing inverter equipment.

About Service Mode Operation

Troubleshooting

Overview: Troubleshooting

Introduction to diagnosing and solving problems based on error codes and symptoms.

Solving Problems Based on Error Codes

Procedure for correcting issues based on displayed malfunction codes.

Error Codes: Overview

A table listing main codes, sub codes, causes, and solutions for system malfunctions.

Symptoms that are NOT System Malfunctions

Solving Problems Based on Symptoms

Relocation

Disposal

Glossary

Daikin RYMQ12T7Y1B Specifications

General IconGeneral
BrandDaikin
ModelRYMQ12T7Y1B
CategoryAir Conditioner
LanguageEnglish