Questions and Answers

  • M
    Mario SmithAug 15, 2025
    Why Daikin RYS35BVMB Air Conditioner is not turning on? (OPERATION lamp is off)
    • S
      stanleydanielleAug 15, 2025
      If your Daikin Air Conditioner isn't turning on and the OPERATION lamp is off, check the following: * Ensure the breaker hasn't been turned OFF or a fuse hasn't blown. * Verify that there isn't a power failure. * Confirm that batteries are correctly installed in the remote controller. * Check if the timer setting is correct.
  • J
    Janet OsborneAug 18, 2025
    What to do if Daikin RYS35BVMB operation stops suddenly? (OPERATION lamp is on)
    • C
      Corey AdamsAug 18, 2025
      If your Daikin Air Conditioner stops suddenly and the OPERATION lamp is on, it might be due to a sudden large voltage fluctuation. For system protection, the air conditioner automatically resumes operation in about 3 minutes.
  • A
    Amy HernandezAug 21, 2025
    Why Daikin RYS35BVMB operation does not start soon?
    • K
      Kim RoweAug 21, 2025
      If your Daikin Air Conditioner doesn't start immediately after pressing the ON/OFF button soon after stopping or reselecting the mode, wait for about 3 minutes.
  • X
    xwileyAug 26, 2025
    Why Daikin RYS35BVMB outdoor unit emits water or steam?
    • J
      Jordan MartinezAug 26, 2025
      The outdoor unit of your Daikin Air Conditioner may emit water or steam. This can occur in HEAT mode when frost on the outdoor unit melts during defrost operation. In COOL or DRY mode, moisture in the air can condense on the cool surface of the outdoor unit piping and drip.
  • C
    Cheryl WangAug 28, 2025
    How to improve cooling (heating) effect of Daikin RYS35BVMB Air Conditioner?
    • G
      garzajohnnyAug 28, 2025
      If you're experiencing poor cooling or heating with your Daikin Air Conditioner, consider these points: * Ensure the air filters are clean. * Make sure nothing is blocking the air inlet or outlet of the indoor and outdoor units. * Verify that the temperature setting is appropriate. * Confirm that windows and doors are closed. * Check if the airflow rate and direction are set correctly. * Check if the unit is set to the INTELLIGENT EYE mode.
  • A
    Anne DaltonSep 1, 2025
    Why my Daikin RYS35BVMB smells bad?
    • L
      Lisa VargasSep 1, 2025
      If your Daikin Air Conditioner's indoor unit is emitting an odor, it's likely due to smells from the room, furniture, or cigarettes being absorbed into the unit and discharged with the airflow. If this occurs, it is recommended to have the indoor unit cleaned by a technician.
  • L
    Laura RamseySep 4, 2025
    Why Daikin RYS35BVMB hot air does not flow out soon after the start of heating operation?
    • A
      Austin WiseSep 4, 2025
      If hot air doesn't flow out immediately after starting the heating operation on your Daikin Air Conditioner, allow 1 to 4 minutes for the system to warm up. The system is designed to discharge air only after reaching a certain temperature.
  • C
    Craig MurraySep 7, 2025
    Why Daikin Air Conditioner heating operation stops suddenly and a flowing sound is heard?
    • A
      anaadkinsSep 8, 2025
      If the heating operation on your Daikin Air Conditioner stops suddenly and you hear a flowing sound, the system is likely removing frost from the outdoor unit. Wait for about 3 to 8 minutes.
  • J
    Joshua RossSep 12, 2025
    Why does Daikin Air Conditioner release mists from the indoor unit?
    • M
      Madeline SmithSep 12, 2025
      Mists may come out of the indoor unit of your Daikin Air Conditioner when the air in the room is cooled into mist by the cold airflow during cooling operation.

Summary

Part 1 List of Function

Functions Overview

Details the cooling and heat pump functions available for the series.

Part 2 Specifications

Cooling Only Specifications

Provides detailed technical specifications for cooling-only models.

Heat Pump Specifications

Provides detailed technical specifications for heat pump models.

Part 3 Printed Circuit Board Connector Wiring Diagram

Part 5 System Configuration

Safety Precautions for Installation

Essential safety guidelines to follow before operating the unit.

Part 7 Removal Procedure

Part 6 Service Diagnosis

Diagnosis Safety Cautions

Important warnings and procedures before starting any diagnostic checks.