REMOVAL
PROCEDURE
SERVICE MANUAL
5.0/6.0/7.1/8.0 kW Class
18000/24000/28000 Btu/h Class
Outdoor Unit
Inverter / Hybrid
Pair Type
Si00-876
Question and Answer IconNeed help?

Do you have a question about the Daikin RYS50B2VMB and is the answer not in the manual?

Summary

Removal of Outer Panels

Removal of Outdoor Fan; Fan Motor

Disconnect Fan Motor Connector

Disconnect the fan motor connector.

Removal of PCBs; Electrical Box

PCB Removal

Remove service monitor and main PCBs after unfastening hooks.

Final PCB and Compressor Connections

Disconnect main PCB connectors and compressor relay connector.

Removal of the Four Way Valve

Loosen Four Way Valve Coil Screw

Loosen the screw of the four way valve coil.

Heat and Disconnect Four Way Valve Brazed Parts

Heat and disconnect brazed parts of the four way valve.

Removal of Electronic Expansion Valve

Remove Putty and Heat Brazed Parts

Remove putty sheets and heat brazed parts for removal.

Removal of Compressor

Remove Compressor Nut and Heat Brazed Parts

Remove compressor nut, heat and disconnect discharge/suction sides.

Lift and Remove Compressor

Lift the compressor up and remove it.

Daikin RYS50B2VMB Specifications

General IconGeneral
CategoryAir Conditioner
ModelRYS50B2VMB
TypeSplit System
Cooling Capacity5.0 kW
Power Supply220-240V, 50Hz
Indoor Unit Dimensions990 x 298 x 212 mm
Outdoor Unit Dimensions845 x 595 x 300 mm
Weight (Indoor Unit)13.5 kg
Weight (Outdoor Unit)36 kg
Indoor Unit Dimensions (WxHxD)990 x 298 x 212 mm
Outdoor Unit Dimensions (WxHxD)845 x 595 x 300 mm
Indoor Unit Weight13.5 kg
Outdoor Unit Weight36 kg
RefrigerantR410A

Related product manuals