Daikin RZQ125C7V1B Service Manual

Daikin RZQ125C7V1B
501 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Pocket
Manual
Service Diagnosis
Si20 - 701_B

Table of Contents

Other manuals for Daikin RZQ125C7V1B

Question and Answer IconNeed help?

Do you have a question about the Daikin RZQ125C7V1B and is the answer not in the manual?

Daikin RZQ125C7V1B Specifications

General IconGeneral
Cooling Capacity12.5 kW
Heating Capacity14.0 kW
Power Supply3 Phase, 380-415 V, 50Hz
Indoor Unit Dimensions (HxWxD)300 x 1000 x 250 mm
Outdoor Unit Dimensions (HxWxD)800 x 900 x 320 mm
Cooling Capacity (kW)12.5 kW
Seasonal Energy Efficiency Ratio (SEER)6.1
Noise Level (Outdoor Unit)52 dB(A)
RefrigerantR32

Summary

2. Symptom-based Troubleshooting

2.2 Equipment does not Operate

Details troubleshooting steps for when the equipment fails to operate.

2.3 Indoor Unit Fan Operates, but Compressor does not Operate

Addresses scenarios where the indoor fan runs but the compressor does not.

2.4 Cooling / Heating Operation Starts but Stops Immediately

Troubleshooting for operations that start and then stop abruptly.

2.5 After Unit Shuts Down, It cannot be Restarted for a While

Explains issues with restarting the unit after shutdown.

2.6 Equipment Operates but does not Provide Cooling

Troubleshooting for units operating but not providing cooling.

2.7 Equipment Operates but does not Provide Heating

Troubleshooting for units operating but not providing heating.

3. Troubleshooting by Remote Controller

3.1 Procedure of Self-diagnosis by Remote Controller

Details the process of performing self-diagnosis using the remote controller.

3.2 Error Codes and Description

Lists and describes various error codes for indoor units.

3.3 Detailed Error Codes

Provides detailed explanations and diagnostic steps for specific error codes.

3.4 A0 Error of External Protection Device

Troubleshooting for external protection device errors.

3.5 A1 Indoor Unit PCB Abnormality

Addresses abnormalities related to the indoor unit PCB.

3.6 A3 Drain Water Level System Abnormality

Troubleshooting for drain water level system abnormalities.

3.7 A6 Indoor Unit Fan Motor Abnormality

Details issues with the indoor unit fan motor.

3.11 A9 Electronic Expansion Valve Coil (Y1E) Abnormality

Addresses abnormalities in the electronic expansion valve coil.

3.12 AF Drain System Abnormality

Troubleshooting for drain system abnormalities.

3.15 C1 Transmission Error (between Indoor Unit PCB and Fan PCB)

Addresses transmission errors between indoor unit PCB and fan PCB.