REMOVAL
PROCEDURE
SERVICE MANUAL
Outdoor Unit
Inverter
Pair Type
3 HP Class
Si281311
Question and Answer IconNeed help?

Do you have a question about the Daikin RZQ71KBV4A and is the answer not in the manual?

Daikin RZQ71KBV4A Specifications

General IconGeneral
BrandDaikin
ModelRZQ71KBV4A
CategoryHeat Pump
LanguageEnglish

Summary

Procedure to Remove Outside Panels and Related Parts

Procedure to Remove Propeller Fan and Fan Motor

Remove Propeller Fan

Procedure to remove the propeller fan by detaching screws and nut.

Remove Fan Motor

Procedure to remove the fan motor by disconnecting the connector and bolts.

Procedure to Remove Switch Box

Remove Wirings and Related Parts

Disconnect wirings and remove related components like fan motor, pressure sensor, and valves.

Remove Switch Box

Unscrew the switch box and lift it out after releasing hooks.

Procedure to Remove PCB Assy (1)

Remove PCB for Display (A2P)

Disconnect connectors and release hooks to remove the display PCB.

Procedure to Remove PCB Assy (2)

Remove Mounting Plate for Electric Component

Disconnect connectors, cut clamps, and remove the mounting plate for the electric component.

Procedure to Remove PCB Assy (3)

Remove PCB Assy (A1P)

Disconnect connectors, remove fixing screw, and release hooks to remove the PCB assembly.

Procedure to Remove Low Pressure Sensor, Electronic Expansion Valve, and Others

Remove Pressure Sensor

Disconnect connector and cut brazing to remove the pressure sensor.

Remove Pressure Switch

Remove lead wire and cut brazing to detach the pressure switch.

Remove Electronic Expansion Valve

Pull out coil and cut brazing to remove the expansion valve body.

Procedure to Remove Thermistor

Procedure to Remove Four Way Valve

Remove Four Way Valve

Remove the valve after detaching one screw and collecting refrigerant.

Remove Main Unit of Four Way Valve

Cut brazings at four locations to detach the main unit of the four way valve.

Procedure to Remove Compressor