EasyManua.ls Logo

Daikin Siesta ATXC20DV1B - Indoor Installation Guideline

Daikin Siesta ATXC20DV1B
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
INDOOR INSTALLATION GUIDELINE
INSTALLING THE MOUNTING PLATE
The mounting plate should be installed on
a wall which can support the weight of the
indoor unit.
1)
Temporarily secure the mounting plate to the
wall, make sure that the panel is completely
level, and mark the drilling points on the wall.
2)
Secure the mounting plate to the wall with
screws.
Recommended mounting plate retention spots and dimensions
Mounting
plate
The mounting plate should
be installed on a wall
which can support the
weight of the indoor unit.
Mounting plate fixing screw
INDOOR UNIT ATXC20/25/35/50
y
Recommended mounting plate
retention spots (7 spots in all)
Place a level er on these tabs.
Use a t ape meas ure as shown.
Position the end of the tape
measure at
Z
117 116.5
Ø65
Ø65
49.5
170
50
770
170
49.5
Through-the-wall
hole Ø 65mm
Drain hose position
unit : mm
All dimensions are in mm
INDOOR UNIT ATXC60/71
y
Recommended mounting plate
retention spots (7 spots in all) Place a leveler on these tabs.
Use a tape measure as shown.
Position the end of the tape
measure at Z
117 126.5
Ø65
Ø65
49.5
170
60
990
170
65.5
Throu
h-t he-wall
hole Ø 65mm
Dr
ain hose position
unit : mm
All dimensions are in mm
DRILLING A WALL HOLE AND INSTALLING WALL EMBEDDED PIPE
For walls containing metal frame or metal board, be sure to use a wall embedded pipe and wall cover in the feed-through
hole to prevent possible heat, electrical shock, or fire.
Be sure to caulk the gaps around the pipes with caulking material to
prevent water leakage.
1)
Drill a feed-through hole of 65mm in the wall so it has a down slope
toward the outside.
2)
Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4)
After completing refrigerant piping, wiring, and drain piping, caulk
pipe hole gap with putty.
Inside
Wall embedded pipe
(
Field suppl
y)
Outside
Caulking (Putty)
(Field supply)
Wall hole cover
(Field
supply)
Ø
65
Wall embedded pipe
(
Field suppl
y)
5
45.4
251.6
46.4
241.6
46.4
241.6
45.4
251.6

Related product manuals