Wiring Diagrams SiBE121021_C
486 Appendix
4MXS68F2V1B
4MXS80E2V3B, 4AMX80E2V3B
indoor
outdoor
FIELD WIRING
9
BLK
BLU
1
N
BLU
S102
RED
S20
RED
4
WHT
3
WHT
BLK
Y1R
2
1 9
RED
A
A
WHT
2
(ROOM-B)
V
R9T
RED
SW3
LED
<GAS PIPE>
BLU
R8T R5T
S21
5
L
BLU
BLU
YLW
Z2C
WHT
BLU
1
U
3
1
BLU
1
M1F
6(P)
B
YLW
U
Z5C
BLK
2
3
1
S15
1
8
S70
3.15A
1
M
ROOM D
S92
WHT
1
ORG
ROOM C
3
MRM20
BLU
S2
8
3~
D
7(N)
BLU
S80
YLW
GRN
BLU
BLU
S90
V3
ORG
GRY
C
AC2
PCB2
SW5
RED
2
GRY
1
12
2
L1R
SHEET METAL
YLW
BLU
6
V9
HR2
5
WHT
M
6
D
GRN
BRN
YLW
RED
BLK
BLK
WHT
BRN
E1
BLU
2
BLU
BLK
RED
1
BLU
S22
BRN
POWER SUPPLY
1
V100
YLW
GRN
Y2E
2
BLK
BRN
RED
S101
1
YLW
Z3C
MRC/W
SW2
Q1L
1
X2M
R2T
S51
B
GRN
2
BRN
6
PM1
2
1
M1C
YLW
X4M
L
3
SA2
N
(CONDENSER)
4
BLK
1
BLU
WHT
E2
S10
BLU
FU2
V
3
12
RED
BLU
S93
YLW
M
3
ORG
WHT
BLK
ORG
YLW
BRN
3
M
X1M
WHT
BLU
BLK
7
W
BLU
3
6
3
M
SW1
R6T
BLU
1
R3T
3
C
<LIQUID PIPE>
BLK
S40
1
V5
1
S23
M
BLK
R10T
1
W
FU3
V2
Z4C
Y1E
5
5
PCB1
30A
RED
X11A
A
Y4E
R4T
X5M
AC1
X3M
RED
7
3
R1T
BLU
ORG
1
R11T
WHT
MRM10
(ROOM-A)
Y3E
1
FU1
(OUTDOOR)
Z6C
ROOM A
1
1
R7T
3.15A
BLU
BRN
6
WHT
S52
BLU
SW4
2
BLU
WHT
1
1
HR1
Z1C
4
ORG
+++
t° t° t° t° t° t° t° t° t°t° t°
(DISCHARGE) (ROOM-C)
(ROOM-D) (ROOM-B)
(ROOM-A) (ROOM-C)
(ROOM-D)
TO INDOOR UNIT
ROOM B
Z1C~Z6C
X1M~X5M
Y1E~Y4E
V2, V3, V5, V9, V100
SA2
FU1, FU2, FU3
AC1, AC2
U, V, W, X11A
E1, E2
HR1, HR2
: FERRITE CORE
: TERMINAL STRIP
: ELECTRONIC EXPANSION VALVE COIL
: VARISTOR
: SURGE ARRESTER
: FUSE
: CONNECTOR
MRM10, MRM20
MRC/W
R1T~R11T
S2~S102
LED1~LED4
LEDA
: MAGNETIC RELAY
: THERMISTOR
: CONNECTOR
: PILOT LAMP
L
N
SW1
SW2
SW3
SW4
SW5
: LIVE
: NEUTRAL
: FORCED OPERATION ON/OFF SW (SW1)
: SELECT SW (SW2)
: WIRING ERROR CHECK SW (SW3)
: PRIORITY ROOM SETTING SW (SW4)
: NIGHT QUIET MODE SETTING SW (SW5)
M1C
M1F
L1R
Q1L
PM1
PCB1, 2
Y1R
SHEET METAL
: COMPRESSOR MOTOR
: FAN MOTOR
: REACTOR
: OVERLOAD PROTECTOR
: POWER MODULE
: PRINTED CIRCUIT BOARD
: REVERSING SOLENOID VALVE COIL
: TERMINAL STRIP FIXED PLATE
3D055495
2TW57576-1
Room C
Room A
Room C
Room A
Condenser
Discharge
Room B
Outdoor
Room A
Room C
Room B
Room D
Gas pipe
Liquid pipe
Room D
Room D
Indoor
Outdoor
Sheet
metal
To indoor unit
Room B
BLK: Black
BRN: brown
WHT: White
RED: Red
BLU: Blue
GRY: Grey
ORG: Orange
YLW: Yellow
GRN: Green
L: Live, N: Neutral, : Field wiring
: Terminal strip : Connector : Connection
: Protective earth (screw) : Relay connector
: Terminal
Z1C~Z6C
X1M~X5M
Y1E~Y4E
V2,V3,V5
V9,V100
SA2
FU1,FU2,FU3
AC1,AC2
U,V,W,X11A
E1,E2E
HR1,HR2
MRM10,MRM20
MRC/W
: Ferrite core
: Terminal strip
: Electronic expansion valve coil
: Varistor
: Surge arrester
: Fuse
: Connector
: Magnetic relay
R1T~R3T
R4T~R7T
R8T~R11T
S2~S102
LED1~LED4
LEDA
SW1
SW2
SW3
SW4
SW5
M1C
M1F
L1R
: Thermistor
: Connector
: Light emitting diode
: Forced operation on/off switch (SW1)
: Operation mode select SW (SW2)
: Wiring error check SW (SW3)
: Priority room setting SW (SW4)
: Night quiet mode setting SW (SW5)
: Compressor motor
: Fan motor
: Reactor
Q1L
PM1
PCB1,2
Y1R
Sheet metal
F2U
Q1DI
: Overload protector
: Power module
: Printed circuit board
: Four way valve coil
: Terminal strip fixed plate
: Field fuse
: Field earth leakage breaker
(300mA)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi NX 4MKS58E3V1B and is the answer not in the manual?

Daikin Super Multi NX 4MKS58E3V1B Specifications

General IconGeneral
BrandDaikin
ModelSuper Multi NX 4MKS58E3V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals