Page #232 background imageLoading...
Page #232 background image
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series SiBE121021_C
220 Operation Manual
Operation manual
7
BRC1D528
Remote controller
4PW23717-1
ADDITIONAL FEATURES OF THE CONTROLLER
Schedule timer operation
NOTE
NOTE
Press the and buttons
simultaneously to enable the LEAVE HOME function.
KEEP IN MIND THAT THE BUTTON
MUST BE OFF TO GUARANTEE
TRIGGERING OF THE LEAVE HOME
FUNCTION.
Use the button to adjust the air flow direction.
Press the button to switch between fixed or variable
air flow direction. Use the icon to determine the
fixed air flow direction by pressing the button
when the icon indicates the desired direction.
Even if fixed air flow direction is selected,
variable air flow direction can be enabled
automatically to preserve proper
operation of your installation.
In schedule timer operation, the installation is also
controlled by the schedule timer. The actions
programmed in the schedule timer will be executed
automatically.
The schedule timer always executes the last
command; this means the user can temporarily
overrule the last executed programmed action. Refer
to "Manual operation" on page 5. The next
programmed action (in the schedule timer) will return
control to the schedule timer.
Use the button to enable or disable the
schedule timer.
The schedule timer overrules the
button, only use the button to
enable or disable the schedule timer. The
schedule timer is enabled when the
icon is visible. The button only
overrules the schedule timer until the next
programmed action.
The programmed schedule is time driven.
Make sure that the clock and day of the week
are set correctly. Refer to "CLOCK SETTING
FUNCTION" on page 4.
Manually adjust the clock for summertime
and wintertime. Refer to "CLOCK SETTING
FUNCTION" on page 4.
A power failure exceeding 1 hour will reset
the clock and the day of the week. Refer to
"CLOCK SETTING FUNCTION" on page 4
to adjust the clock and the day of the week.
The actions programmed in the schedule
timer will not be lost after a power failure;
reprogramming the schedule timer is not
required.
To set up the SCHEDULE TIMER refer to chapter 6.
"Programming the schedule timer" on page 10.
1 LEAVE HOME
2 Adjusting the air flow direction
3 SCHEDULE TIMER
All features and operation and programming of the
schedule timer are described below.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi NX FFQ50B8V1B and is the answer not in the manual?

Daikin Super Multi NX FFQ50B8V1B Specifications

General IconGeneral
BrandDaikin
ModelSuper Multi NX FFQ50B8V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals