Outdoor Unit - 50~75 Class SiBE121021_C
376 Removal Procedure
2
Detach the fixing tape
of the electrical box
cover.
3
Unfasten the 4 hooks at
the mark of the
electrical box cover.
4
Lift the electrical box
cover up and remove it.
5
Disconnect the
connector for the fan
motor [S70].
Step
Procedure Points
(R5512)
Fixing
tape
[S70]