OPERATING
INSTRUCTIONS
"
(^)"(POWER):
Press
the
POWER
keypad
to
turn
the
unit
on/off.
^TEMPERATURE
SETTINGS:
Press
the
up
keypad
to
increase
the
set
(operating)
temperature
of
the
air
conditioner.
Each
time
the
keypad
is
pressed
the
temperature
is
increased
as
follows;
2°F
(Farenheight
Scale)
Maximum
Setting
90°F
1°C
(Celsius
Scale)
Maximum
Setting
31°C
1|FTEMPERATURE
SETTINGS:
Press
the
down
keypad
to
decrease
the
set
(operating)
temperature
of
the
air
conditioner.
Each
time
the
keypad
is
pressed
the
temperature
is
decreased
as
follows;
2“F
(Farenheight
Scale)
Minimum
Setting
60°F
1°C
(Celsius
Scale)
Minimum
Setting
16°C
"A"(
SWING
Press
the
SWING
keypad
to
activate
the
automatic
air
swing
(oscillation)
feature.
The
green
pilot
light
adjacent
to
the
SWING
keypad
will
illuminate,
identifying
the
selected
mode
is
operational.
The
vertical
louvers
will
oscillate
back
and
forth
(side
to
side)
automatically
sweeping
cold
air
alternately
for
comfortable
cooling.
To
stop
the
air
swing
feature,
press
the
SWING
keypad
again,
the
green
pilot
light
adjacent
to
the
keypad
will
go
off.
"tfi
"(ENERGY
SAVER):
To
activate
the
ENERGY
SAVER
feature,press
and
hold
the
'^J’(SWING)
keypad
for
3
seconds.
The
green
pilot
light
directly
above
the
ENERGY
SAVER
mode
will
illuminate,
identfying
the
selected
mode
is
operational.
The
ENERGY
SAVER
program
helps
to
reduce
energy
(electricity)
consumption
by
controlling
(limiting)
operation
of
the
fan
motor
with
the
operation
(cycles)
of
the
compressor,
i.e.
compressor
off
/
fan
off
compressor
on
/
fan
on
If
the
ENERGY
SAVER
feature
is
not
activated,
the
fan
will
operate
continuously,
even
after
the
compressor
has
cycled
off.
i.e.
compressor
on
/
fan
on
compressor
off
/
fan
on
NOTE:
The
energy
saver
feature
operates
in
“cooling”
mode
only.
MODE:
P
ress
this
keypad
to
select
the
appropriate
operating
mode.
(Fan
/
Cool)
Each
depression
of
the
MODE
keypad
will
alternate
between
the
“COOLING”
and
“FAN”
mode.
The
green
pilot
light
directly
above
the
COOL
or
FAN
mode
will
illuminate,
identifying
the
selected
mode
is
operational.
\D
"(TIMER).
Press
this
keypad
to
activate
the
“auto
start
/
auto
stop”
timer
programs.
Auto
start/stop
programs
can
be
programmed
from
0
~
12
hours.
Each
depression
of
the
TIMER
keypad
will
increases
the
selected
time
in
1
hour
increments.
AUTO
-START:
Before
activating
the
“auto
-
start”
program,
you
must
first
select
(set)
the
operating
conditions
of
the
air
conditioner,
(i.e.
temperature
setting
and
fan
speed).
Once
the
settings
are
complete,
the
air
conditioner
must
be
switched
off.
(non-operational)
Depress
the
TIMER
keypad
and
the
auto-start
time
will
appear
in
the
LED
display,
select
the
required
time
(0
~
12hours)
and
the
air
conditioner
will
start
automatically
at
the
established
time.
AUTO
-STOP:
Turn
the
air
conditioner
on
and
select
the
required
operating
conditions,
(i.e.
temperature
setting
and
fan
speed).
Depress
the
TIMER
keypad
and
the
time
will
appear
in
the
LED
display,
select
the
required
auto
stop
time,
(0
~
12hours)
and
the
air
conditioner
will
stop
automatically
at
the
established
time.
NOTE:
It
is
not
possible
to
operate
both
the
“auto-start”
and
“auto-stop”
feature
within
a
single
program.
All
auto-timed
programs
are
automatically
erased
after
the
set
program
is
complete.
"SCFHONE
TOUCH):
Press
tnis
keypad
to
activate
a
pre-set
(factory)
temperature
setting
of
22°C
+
/
-
2°C
(71.6°F).
The
air
conditioner
will
operate
and
maintain
the
indoor
temperature
at
this
setting.
ii