Troubleshooting
Constant Ice full with no ice present:
1. The black eyes, inside on the sides just above the ice bucket dirty
2. Photoelectric Diodes #25 Bad
Fix : first clean the eyes with Q-tip and alcohol. If problem persists,
replace the photoelectric diodes.
Constant Fill when tank is not empty:
The water full sensor is either clogged or bad
Fix: Run through the self-clean mode with 50/50 vinegar water mix.
To Enga
g
e Self clean turn unit off then press the up and down
arrows together twice within 5 seconds.
If the problem persists the water sensor* will have to be replaced.
*At this time the water sensor is Not shown on the breakdown and no part
number is available. It is located exactly where #57 points to on the
exploded view.