7
PROBLEM POSSIBLE CAUSE
No power • A fuse may be blown or the circuit breaker tripped
• Plug not fully inserted into the wall outlet
Internal temperature not cold enough
Appliance runs continuously
• Door is not shut properly or opened excessively
• Exhaust vent is obstructed
• Recently added a large quantity of warm contents to the
cabinet
• Close proximity to heat source or direct sunlight
• Ambient temperature or humidity is very high
• Possible system leak, evaporator fan failure or compressor
failure
Condensation on the cabinet or door • Door is not shut properly or opened excessively
• Ambient temperature or humidity is very high