5000 SyncPos option
MG.10.J4.02 – VLT is a registered Danfoss trade mark
162
Messages and Error Reference
■ Error in array ...
SyncPos
Error in array part of file.
Meaning
When re-saving a configuration ("CONTROLLER"
→→
→→
→ "PARAMETERS"
→→
→→
→ "RESTORE FROM FILE")
the computer recognizes that the data in the array
area is formatted incorrectly.
Cause
In order to be able to save a file, the following
conditions must be fulfilled:
• Identical software versions
• same configuration (e.g. same number of
axes)
• In the case that arrays have already been in-
putted, these must match the ones that are to
be saved in terms of type and size.
■ Error in axis parameter ...
SyncPos
Error in axis parameter part of file.
Meaning
When re-saving a configuration ("CONTROLLER"
→→
→→
→ "PARAMETERS"
→→
→→
→ "RESTORE FROM FILE")
the computer recognizes that the data in the area
of the axis parameters is formatted incorrectly. The
parameter number and the sequence must be cor-
rect and numbering must be continuous.
Cause
In order to be able to save a file, the following
conditions must be fulfilled:
• Identical software versions, that provides
same number and order of the parameters
• same configuration (e.g. same number of
axes)