of United Kingdom Building Regulations and EN12897:2006.
The information is entirely valid in a UK specific installation.
Weight when full 286 kg
PT valve replacement no. 086U8267
Oper. temp non self-reset. thermostat 88˚C
Maximum flow temperature 65˚C
Operating pressure heat source 1 bar
Primary heating power input 9 kW
Primary flow rate 0,16−0,31 l/s
Actual capacity 180 liter
Standing heat loss 1,8 kWh / 24 h
Maximum water supply pressure 10 bar
Pressure reducing valve 3 bar
Expansion valve 6 bar
Expansion vessel charge pressure 3 bar
Operating pressure 5,5 bar
Temp and pressure release valve 10 bar; 90−95˚C
Maximum primary working pressure 1,5 bar
Immersion heater D76 / 9 kW / 230 V
WARNING TO THE USER
a)
Do not remove or adjust any component part of this
unvented water heater. Contact the installer.
b)
If this unvented water heater develops a fault, such
as a flow
of hot water from the discharge pipe,
switch the heater off and contact the installer.
WARNING TO THE INSTALLER
a)
This installation is subject to Building Regulations notification.
b)
Use only appropriate components for installation and maintenance.
c) INSTALLED BY:
Name.___ __ __ ___ __ __ __ __ __ _____ __ __ __ __ _____
Address.__ __ __ __ __ _____ __ __ __ __ _____ __ __ __ __
Tel No._____ __ __ __ __ __ ___ __ __ __ __ __ ___ __ __ __
Completion date.__ __ __ __ __ _____ __ __ __ __ __ ___ _