3.1.10 Speed (rpm) control
A heat pump requires optimum conditions in the heating system in
order to be able to run as efficiently as possible. The temperature differ-
ence between the heating system’s supply line and return line must be
constant between 7–10°C. If the differences are greater or less, the heat
pump is less efficient and savings are lower.
The speed controlled circulation pump in DHP-AQ always ensures that the
temperature difference is retained. The control equipment detects if the
balance is upset and increases or decreases the speed of the circulation
pump as necessary.