Sub menu INFORMATION -> DEFROST (DHP-A, -AL)
The menu applies to DHP-A, -AL with defroster card and only appears if OUTDOOR AIR in the SERVICE -> INSTALLATION -> SYSTEM -> HEAT
SOURCE menu is selected. Used to obtain information about outdoor unit defrosting and to make certain settings.
Menu selection Meaning Factory setting
DEFROSTS Total number of defrosts carried out. -
BETW. 2 DEFR The operating time of the compressor in minutes between the 2 last defrosts. -
TIME SINCE DEFROST The operating time of the compressor in minutes since last defrost. -
FAN H OFF AT Fan high speed is deactivated at this temperature and low speed is activated. 12°C
(interval: 10°C / 20°C)
DEFROST CURVE Here, the angle of the defrost curve can be changed using the right-hand arrow
andbyeitherpressing+or–(Changethestarttemperaturefordefrost).
-10°C
(interval: -13°C / -7°C)
MANUEL DEFR Byusingtheright-handarrow+or-,defrostcanbestartedmanually(shunts
+20°Cfor10minutes).
0 (interval: 0 / 1)