DHP-C 6 8 10 4H 5H 7H
R407C R407C R407C R134a R134a R134a
1,20 1,30 1,45 0,90 1,00 1,10
3,4 3,4 3,4 3,2 3,2 3,2
3,1 3,1 3,1 2,45 2,45 2,45
400 400 400 400 400 400
2,0 2,3 3,6 2,0 2,3 3,6
0,2 0,2 0,4 0,2 0,2 0,3
3/6/9 3/6/9 3/6/9 3/6/9 3/6/9 3/6/9
12 10 18 12 10 18
10
4
/16
5
/20
6
16
4
/16
5
/20
6
16
4
/16
5
/20
6
10
4
/16
5
/20
6
16
4
/16
5
/20
6
16
4
/16
5
/20
6
* * * * * *
* * * * * *
* * * * * *
* * * * * *
* * * * * *
* * * * * *
5,33 7,51 9,40 - - -
4,04 4,34 4,24 - - -
5,38 7,40 9,24 3,20 4,50 5,50
3,41 3,57 3,51 2,70 2,90 2,90
1,3 1,7 2,2 - - -
0,36 0,49 0,62 0,20 0,28 0,37
0,14 0,19 0,24 0,08 0,12 0,14
39 39 78 43 63 60
51 44 40 47 50 43
20/-10 20/-10 20/-10 20/-10 20/-10 20/-10
55/20 55/20 55/20 65/20 65/20 65/20
0,08 0,08 0,08 0,03 0,03 0,03
2,65/2,85 2,65/2,85 2,65/2,85 1,80 1,80 1,80
3,10 3,10 3,10 2,45 2,45 2,45
180 180 180 180 180 180
1,6 1,9 2,1 1,6 1,9 2,1
0,7 1,2 1,6 0,7 1,2 1,6
* * * * * *
1 1 1 1 1 1
690x596x1845 690x596x1845 690x596x1845 690x596x1845 690x596x1845 690x596x1845
210 215 225 210 215 225
390 395 405 390 395 405
47,3 43,7 45,6 47,3 43,7 45,6
The measurements are performed on a limited number of heat pumps which can cause variations in
the results. Tolerances in the measuring methods can also cause variations.
1)
At B0W35 according to EN 14511 (including circulation pumps).
2)
At B0W45 according to EN 14511 (including circulation pumps).
3)
According to IEC61000.
4)
Heat pump with 3 kW auxiliary heater (1-N 1.5 kW).
5)
Heat pump with 6 kW auxiliary heater (1-N 3 kW).
6)
Heat pump with 9 kW auxiliary heater (1-N 4.5 kW).
7)
Pressure drop that must not be exceeded outside the heat pump without the nominal flow being
reduced. For the cooling circuit these values require a pipe of Ø 40x2.4.
8)
Nominal flow: heating circuit Δ10K, cooling circuit Δ3K.
9)
Fuse protection phase L1 (size 4 is equipped with an 1-phase compressor)
10)
The values apply to a new heat pump with clean heat exchangers.
11)
Sound power level measured according to EN ISO 3741 at BOW45 (EN 12102).
*
)
Not available in this version.
Brine to water heat pump
Refrigerant Type
Amount kg
Test pressure MPa
Design pressure MPa
Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll
Oil POE POE POE POE POE POE
Electrical data
3-N~50Hz
Main supply Volt
Rated power compressor kW
Rated power, circ.pumps kW
Auxiliary heater, 3 steps kW
Start current
3
A
Circuit breaker A
Electrical data
1-N~50Hz
Main supply Volt
Rated power compressor kW
Rated power, circ.pumps kW
Auxiliary heater, 3 steps kW
Start current A
Circuit breaker A
Performance
10
Heating capacity
1
kW
COP
1
Heating capacity
2
kW
COP
2
Power input
1
kW
Nominal flow
8
Cooling circuit l/s
Heating circuit l/s
External available pressure
7
Cooling circuit kPa
Heating circuit kPa
Max/min temperature Cooling circuit
o
C
Heating circuit
o
C
Pressure switches Low pressure MPa
Operating MPa
High pressure MPa
Water volume Water heater l
Condensor
l
Evaporator l
De-superheater l
Anti freeze media Ethylene glycol/
Ethanol
Ethylene glycol/
Ethanol
Ethylene glycol/
Ethanol
Ethylene glycol/
Ethanol
Ethylene glycol/
Ethanol
Ethylene glycol/
Ethanol
Number of units
Dimensions LxWxH mm
Weight empty kg
Weight filled kg
Sound power level
11
dB(A)