16  Manual  RS8DZ702  ©  Danfoss  03-2012                                                                               EKC 202 / 302 
Connections
Power supply
230 V a.c.
Sensors
Sair is thermostat sensors. 
S5 is a defrost sensor and is used if defrost has to be stopped 
based on temperature. It may however also be used as product 
sensor or condenser sensor.
Digital On/O signal
A cut-in input will activate a function. The possible functions are 
described in menu o02. 
Relays
The general connections are:
Refrigeration. The contact will cut in when the controller demands  
                            refrigeration
Defrost.
Fan.
Alarm.   The relay is cut out during normal operation and cuts 
in in alarm situations and when the controller is dead 
(de-energised)
Light.  The contact will cut in when the controller
  demands light.
Electric noise
Cables for sensors, DI inputs and data communication must be 
kept separate from other electric cables:
- Use separate cable trays
- Keep a distance between cables of at least 10 cm
- Long cables at the DI input should be avoided
EKC 202A
EKC 302A
EKC 202B
EKC 302B
EKC 202C
or
or
or