EKC 361 Manual RS8AE802 © Danfoss 12-2009 11
Appendix 1
Interaction between internal and external start/stop functions
and active functions.
Connection between the evaporating temperature and the
actuators temperature (the values are approximate).
n01: The highest regulated room temperature will have a be longing t
o
value which
in turn indicates the value of the n01 setting. Due to tolerances in the actua-
tor, the setting value must be 10 K higher than shown in the curve.
n02: The lowest occurring suction pressure will have a belonging t
o
value which in
turn indicates the value of the n02 setting. Due to tolerances in the actuator,
the setting value must be 10 K lower than shown in the curve.
CVQ KVQ
CVMQ
Appendix 2
Cable length for the CVQ actuator
The actuator must be supplied with 24 V a.c. ± 10%.
To avoid excessive voltage loss in the cable to the actuator, use a
thicker cable for large distances.
Wire cross section
Cable length
Internal Start/stop O O On On
External Start/stop O On O On
Refrigeration O On
Actuator Stand-by Regulating
Actuator temperature "n02" "n02" to "n01"
Fan relay O On
Expansion valve relay O On
Temperature monitoring No Yes
Sensor monitoring Yes Yes