Information (reading only)
Messages
Level 1 Level 2 Description Values Min. Def. Max.
tid
InI Option chosen in the conguration wizard
Pd
1)
Pump down active? 0=No, 1=Yes
PU Program version
Pr Program revision
bU Bootloader version
br Bootloader revision
PAr Parameter map revision
EP Exit to level 1
Messages A R
Pd Pump down malfunction error (Shutdown)
LP Pump down malfunction error (Start-up)
E1/E2/E3
Probe 1/2/3 failure (Open circuit, crossed circuit or temperature outside the limits of the probe)
(Equivalent limits in °F)
Ad0 Open door alarm. Only if the door stays open for a greater time than is indicated in parameter A12
AH Maximum temperature alarm in control probe. The temperature value programmed in A1 has been reached
AL Minimum temperature alarm in control probe. The temperature value programmed in A2 has been reached
AE External alarm activated (by digital input)
AES Severe external alarm activated (by digital input)
Adt Defrost alarm concluded due to time-out. The time established in d1 has been exceeded
HCP
HACCP alarm. The temperature has reached the value of parameter h1 during a longer period than has been
established in h2
hCP + PF
HACCP alarm due to a fault in the power supply. The temperature established in h1 has been reached following a
fault in the power supply
dEF Indicates that a defrost is being performed
PAS Access code (Password) request. See parameters b10 and PAS
S1 - S2
Shown sequentially with the temperature: The controller is in demo mode, the conguration has not been
made.
1)
It can only be modied using the conguration wizard (InI).
A: Activates the acoustic alarm
R: Activates the alarm relay