Flatpack brake resistors for horizontal conveyors
VLT type Motor [kW] Resistor [ohm] Size Order number Max. duty cycle [%]
5001 0.75 630 620 100 W 175U1001 14.0
5001 0.75 630 620 200 W 175U0982 40.0
5002 1.1 430 430 100 W 175U1002 8.0
5002 1.1 430 430 200 W 175U0983 20.0
5003 1.5 320 310 200 W 175U0984 16.0
5004 2.2 215 210 200 W 175U0987 9.0
5005 3 150 150 200 W 175U0989 5.5
5005 3 150 300 200 W
2 x 175U0985
1
12.0
5006 4 120 240 200 W
2 x 175U0986
1
11.0
5008 5.5 82 160 200 W
2 x 175U0988
1
6.5
5011 7.5 65 130 200 W
2 x 175U0990
1
4.0
1. Order 2 pcs.
Mounting angle for flatpack resistor 100 W 175U0011.
Mounting angle for flatpack resistor 200 W 175U0009.
Mounting frame for 1 resistor narrow (slim bookstyle) 175U0002.
Mounting frame for 2 resistors narrow (slim bookstyle) 175U0004.
Mounting frame for 2 resistors broad (wide bookstyle) 175U0003.
See Instruction MI.50.BX.YY for further information.
For 525-600 V and 525-690 V please contact Danfoss.
VLT
®
5000 Series
MG.51.C5.22 - VLT
p
is a registered Danfoss trademark. 37
Technical data

Table of Contents

Other manuals for Danfoss VLT 5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT 5000 Series and is the answer not in the manual?

Danfoss VLT 5000 Series Specifications

General IconGeneral
Frequency50/60 Hz
Cooling MethodForced Air Cooling
EnclosureIP20
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Communication InterfacesRS-485, Profibus