If the unit does not start again contact a DANTHERM dealer. This also applies if the unit is running
but not producing any water. This is probably due to a fault in the cooling circuit, which can only be
repaired by a service engineer.
9. Technical specifications
Model
CDT 22 CDT 35 CDT 50 CDT 85
Working range – humidity %RH 40 - 100
Working range – temperature °C 3 - 30
Power supply V/Hz 230/50
Max. current consumption A 2,9 2,7 4,1 6,9
Max. power consumption kW 0,6 0,7 0,950 1,5
Air volume m
3
/h 280 400 800 1000
Refrigerant - R 407 C R 407 C R 407 C R 407 C
Refrigerant quantity kg 0,300 0,475 0,575 1,600
Capacity of water container l 5,5 12,5 12,5 -
Sound level 1m distance DB(A) 57 59 61 64
Weight kg 41 52 60 74
Model
CDT 35 S
Working range – humidity %RH 40 - 100
Working range – temperature °C 3 - 30
Power supply V/Hz 230/50
Max. current consumption without heating element A 3,7
Max. power consumption without heating element kW 0,9
Max. current consumption with heating element A 8,0
Max. power consumption with heating element kW 1,9
Air volume m
3
/h 650
Refrigerant - R 407 C
Refrigerant quantity kg 0,475
Capacity of water container l 12,5
Sound level 1m distance DB(A) 62
Weight kg 56
9.1 Disposal
This unit contains refrigerant type R407C and compressor oil. When scrapping the unit, bring the
compressor to a place of discharge which is approved by the authorities.
NOTE: If the unit does not work as it should
,
switch it off immediatel