21
060798 • Version 1.4 • 22.01.2019
Fault finding guide, continued
con-
unnecessarily dried
out.
The unit might be operating
with too much air change com-
pared to the size and use of the
house.
Switch to Automatic Demand
Mode or set the air flow rate at
Fan Step 2 or 1 in Manual Op-
eration Mode.
Using Fan Step 2 or 1 is
only recommended for a short
period of time.
Expect a couple of days to raise
humidity, if the house is very
dry.
If that does not help, contact
your installer to adjust the air
the inside of the
windows and other
cold surfaces. (au-
tumn, winter and
spring)
The air change is too low or the
air distribution is unfortunate
which causes too low air
change in critical rooms
Adjust the unit to Automatic
Demand Mode, which assures
that it keeps the humidity on a
suitable level. Do not let the
unit operate on Fan Step 1 or 2
in Manual Operation Mod be-
cause that might not keep the
humidity low enough when the
moisture load of the house is
that big.
operating with the
same speed.
The unit is set on manual oper-
ation at one fixed speed.
Switch the unit to Automatic
Demand Mode after which the
unit will adjust the air flow
rates according to the house’s
needs.
out after a short
period of time, after
which only the
green light-
diode is on.
The display goes into Energy
Saving Mode after 2 minutes to
effect power save.
The unit is operating correctly.