Register Description
Product Reference Guide
23
LAST_SAMPLE_VALUE Register (RO)
Register Address Op. Default
LAST_SAMPLE_VALUE 0x66 RO 0x0000
It represents the last temperature value read from the sensor (even if not
stored in the log memory). LAST_SAMPLE_VALUE register is forced to 0 after
a reset operation.
SAMPLE_NUM Register (RO)
Register Address Op. Default
SAMPLE_NUM 0x67 RO 0x0000
It represents the number of samples present inside the log memory.
SAMPLES_NUM register is forced to 0 after a reset operation.
SHIPPING_DATE Register (RO - 2 words)
Register Address Op. Default
SHIPPING_DATE_L 0x6A RO 0x0000
SHIPPING_DATE_H 0x6B RO 0x0000
The Shipping Date register (expressed in the Unix time format) is used to
store the time when logging was enabled (by RF or, if enabled, by the but-
ton). Default value of SHIPPING_DATE register is 0. SHIPPING_DATE register
is set
to 0 after a reset operation.
STOP_DATE Register (RO - 2 words)
Register Address Op. Default
STOP_DATE_L 0x6C RO 0x0000
STOP_DATE_H 0x6D RO 0x0000
The STOP_DATE register (expressed in the Unix time format) is used to store
the time when logging was stopped (by RF or, if enabled, by the button).
Default value of STOP_DATE register is 0. STOP_DATE register is set to 0
after a reset operation.
USER_AREA Registers (RW - 28 words)
Register Address Op. Default
USER_AREA_0 0x6E RW ...
USER_AREA_1 0x6F RW ...
...... ...... .. ...
USER_AREA_15 0x89 RW ...
User Area is a set of 28 words registers for user defined data storage.