5.1 PARAMETER OVERVIEW
The parameters used to configure the Integra-H units are described in the Radio Service Software (INTRSS)
help file. Section 5 summarizes the Integra-H parameter settings and their variations when used within a network.
Refer to help files for descriptions of the above fields.
Table 5-1 Normal Factory Settings (Units)
Fields Integra-H with Integra-H
Network Settings
Compatibility Mode Integra-TR
Tx/Rx Mode Both Tx and Rx
Extended Preamble (ms) 0
Network Speed 9600, 19200, 21400, 25600
Tx Time Out 30 sec ON
Tx Online Diagnostics Yes
Unit Type Master
Data Delivery All
Suspend Period (ms) 0
Activity Time-out (sec) 5
Sleep Mode Disable (N/A)
COM Port
Device Baud 19200
Data fwd timer Normal
Parity 8 bit, no parity, 1 stop bit
Break Ignore break
Xmit Control DOX
DCD Control Active
Analog Connector
Analog 1 Input or Fan Control
(Units with cooling option)
Analog 2 Input
Frequency
Transmit User choice
Receive User choice
Adjustments
Carrier Sense (-dBm) 105
Power Out 255 (indicates 1 Watts nominal)
Frequency Warp Grayed out (radio dependent)
Values set at factory can be changed, if
required; hit related test button to
enable field
Deviation
RXA Adjust