MAINTENANCE AND INSPECTION
CAUTION:
Always be sure that the tool is switched off and unplugged before attempting to
perform inspection or maintenance.
1.
After Metal Cutting
When cutting metals under extreme working conditions, conductive dust can
accumulate in the interior of the machine and impair its protective insulation.
In such cases, it is recommended to use stationary dust extraction equipment,
to blow out the ventilation slots frequently and to power the tool via a ground
fault circuit interrupter.
2.
Inspecting the Mounting Screws
Regularly inspect all mounting screws and ensure that they are properly
tightened. Should any of the screws be loose, retighten them immediately.
Failure to do so could result in serious hazard.
3.
Maintenance of the Motor
The motor unit winding is the very “heart” of the power tool. Exercise due care
to ensure the winding does not become damaged and /or wet with oil or water.
Always keep the power tool and its ventilation slots clean.
4.
Inspecting of the Blade Roller Guide
The blade roller guide should occasionally be checked for wear and lubricated
with a drop of oil. If it is worn, it must be replaced.
5.
Inspecting and Replacing Carbon Brushes
Remove and check the carbon brushes regularly. Replace when they wear
down to the limit mark. Keep the carbon brushes clean and free to slip in the
holders. Both carbon brushes should be replaced at the same time and use
only identical carbon brushes.
To maintain product SAFETY and RELIABILITY, repairs, any other maintenance
or adjustment should be performed by authorized centers, always using original
replacement parts.