GRILL TROUBLESHOOTING
PROBLEM AREA: WHAT TO DO: USEFUL NOTES:
(Cont'd)-Grill still will
not operate,
(Electrically opera-
tional Steps 1-8 OK)
Low Flame / Heat
from Grill Burner
Too much Heat given
off by Grill Burner
when in "LOW"
position
If dirt or other foreign matter is blocking gas
flow, then the supply line should be disconnect-
ed and the line purged. This procedure is not
covered under war ranty.
2) If gas is present through the Manual
Valve, to the Thermal Valve, and Electrical
continuity of the valve exists per Step 6 above,
remove and visually check the valve orifice for
blockage. If none exists, remove / replace
T her mal Valve
CHECK
1) Gas pr essure and supply as outlined in
the "General" section.
2) If natural gas, ensure the orifice hood is
not tightened down onto the L.P. jet nested within
the Thermal Valve.
3) Adjust the air shutter closed until the
flame is yellow, then open slightly until the yellow
disappears.
1) Adjust center simmer screw per Installation
Instructions. (This procedur e is Installer related and
not covered under war ranty)