36
PAR. PROCEDURE SETTABLE VALUES
PROGRAMMING PROCEDURES
Positioning of operator 1
Unused parameter
Memorization of the motors’ stroke
Deletion of transmitters
Transmitters memorizing
Search and deletion of a transmitter
Restoring the operating parameters
Lock access to programming
How to learn connected DE@NET devices (unused at the moment)
Restoring the “I/O” congurations (input/output)
Downloading data on the external memory unit
Uploading data from an external memory unit
Visualisation of inputs and operations-counter status
Unused parameter
Unused parameter
PAR. PARAMETER DESCRIPTION SETTABLE VALUES
DEFAULT VALUES
24V
INPUTS CONFIGURATION PARAMETERS
INPUT_2 selectioning input type
• 000: IN2 type=free contact
• 001: IN2 type=constant resistance 8K2
Unused parameter
• 000: NONE (unused)
• 001: START (start)
• 002: PED. (pedestrian)
• 003: OPEN (separated open)
• 004: CLOSE (separated close)
• 005: OPEN_PM (man present open)
• 006: CLOSE_PM (man present close)
• 007: NONE (unused)
• 008: PHOTO 1 (photocell 1)
• 009: PHOTO 2 (photocell 2)
• 010: SAFETY 1 (safety rib 1)
• 011: STOP (lock)
• 012: FCA1 (opening limit switches Mot1)
• 013: NONE (unused)
• 014: FCC1 (closing limit switches Mot1)
• 015: NONE (unused)
• 016: SAFETY 2 (safety rib 2)
• 017: NONE (unused)
• 018: NONE (unused)
• 019: NONE (unused)
• 020: SAFETY prevention
/
Unused parameter /
INPUT_1 operating selection IN1
INPUT_2 operating selection IN2
INPUT_3 operating selection IN3
INPUT_4 operating selection IN4

Table of Contents