45
SPACE
SPACE
XL
SPACE
XXL
INPUTS CONFIGURATION
PARAMETERS
Allocation of CHANNEL 1 of remotes
• 000: NONE (unused)
• 001: START (start)
• 002: PEDESTRIAN (pedestrian)
• 003: OPEN (separated open)
• 004: CLOSED (separated close)
• 005: Unused
• 006: Unused
• 007: ELOCK_IN (congurable Output 2. See P062)
• 008: AUX_IN (congurable Output 1. See P066)
• 009: COURTESY_IN (courtesy light control)
CH1
Allocation of CHANNEL 2 of remotes CH2
Allocation of CHANNEL 3 of remotes CH3
Allocation of CHANNEL 4 of remotes CH4
Selection of type of remotes
• 000: HCS x-code
• 001: HCS rolling-code
• 002: Dip-switch
OPERATORS CONFIGURATION
PARAMETERS
Selection type of operators
• 000: ADVANCE - SPACE - VIP 60
• 001: VIP 80
• 002: ADVANCE XL - SPACE XL - VIP XL
• 003: SPACE XXL
Select encoder type
• 001: 1 channel encoder
• 002: 2 channel encoder
Unused parameter
OPERATING PARAMETERS
Operators speed adjustment during slow-down while opening
Warning: by modifying the values of these
parameters, on exiting the programming
mode, a new learning of the motor stroke
will be requested.
15%........................100%
Operators speed adjustment during the stroke while opening 15%........................100%
Operators speed adjustment during the stroke while closing 15%........................100%
Operators speed adjustment during slow-down while closing 15%........................100%
Slow down duration adjustment while opening 0%............................80%
Slow down duration adjustment while closing 0%............................80%
Operator 1 force adjustment while opening (if = 100% obstacle detection deactivated) 1%…...........................100%
Operator n.1 force adjustment while closing (if = 100% obstacle detection deactivated) 1%…...........................100%
Secondary force adjustment in closing: adjusts the motor’s force during the last part of the closing movement dened by P058 1%…...........................100%
Unused parameter
Automatic closing times adjustment (if = 0 automatic closing deactivated)
Warning: automatic closure must be used
only in concomitance with the additional
safety devices!
0sec...................................255sec
Pedestrian automatic closing time adjustment (se = 0 pedestrian automatic closing
deactivated)
0min...................................255min
Pedestrian stroke duration adjustment 5%…...........................50%
Pre-ashing time adjustment 0sec…….10sec
Unused parameter
Unused parameter

Table of Contents