Tab.38 Installation Setup > SCB-10 > Pass.buff.tank 1sens > Parameters, counters, signals > Parameters
Code Display text Description Range Adjust
ment
BP001 Type Buffer Tank Type of buffer tank 0 = Disabled
1 = One sensor
2 = Two sensors
3 = Three sensors
1
Tab.39 Installation Setup > SCB-10 > CIRCC ( Swimming pool ) > Parameters, counters, signals > Parameters
Code Display text Description Range Adjust
ment
CP023 Zone Function Functionality of the zone 0 = Disable
1 = Direct
2 = Mixing Circuit
3 = Swimming pool
4 = High Temperature
5 = Fan Convector
6 DHW tank
7 = Electrical DHW
8 = Time Program
9 = ProcessHeat
10 = DHW Layered
11 = DHW Internal tank
31 = DHW FWS EXT
3
6 Installation
62 AMC 7686707 - v.01 - 06092018